Larson Electronics LLC WWW.
LARSONELECTRONICS
.COM
9419 E US HWY 75, Kemp, TX 75143 - P: 903-498-3363 F: 903-498-3364 E:
sales@
larsonelectronics
.com
LEDSB-3XQF12V-1227-WF-3XKT
INSTALLATION AND MOUNTING
Magnetic Mounting:
WARNING:
As with any magnetically mounted warning device, its use on the exterior of a moving
vehicle is at the sole discretion and responsibility of the user.
This magnetic mount provides a secure, temporary installation in most circumstances and is
recommended for stationary use only.
The magnetic based beacon provides a secure, temporary installation. The beacon should be placed in
the center of the roof where the least amount of curvature occurs. Check the magnet for debris before
installation. Any foreign matter can reduce holding power and scratch the vehicle. The roof surface
should be dry and have a dull, not glossy finish. A glossy, highly waxed surface will reduce the magnet’s
holding power. When placed, the beacon should adhere firmly. The user should not attempt to drive
with the beacon in place should the unit slide or move easily.
Voltage:
120-277 V AC Stepped Down to 10-30V DC
Permanent Mounting:
The permanent mount beacon provides a secure, permanent installation. Use the supplied foam
gasket and screws to mount the beacon in the desired location. Wire routing should be taken into
consideration when choosing a mounting location.
Pipe Mounting (optional):
The beacon base will accept a standard 1" NPT pipe. Hand tighten the beacon base on the pipe thread
until the pipe bottoms out inside the unit.
DO NOT
over tighten- Base is plastic.
WIRING INSTRUCTIONS
Magnetic Mounting:
The magnetic mount beacon is equipped with a light plug rocker switch, that plugs into a 12 Volt DC
cigarette lighter outlet; rotate and push with reasonable moderate force to insure the best possible
connection.
Permanent Mounting:
The beacon is terminated with a 6" long 4-wire cable harness that may be connected as follows:
Color
Function
Connect To
Red
Power
+VDC
Black
Ground
Chassis Ground
Blue
Pattern Switching Chassis Ground to Activate
Yellow
Synchronization
See Synchronization Section