Solid-state Frequency Converter

Mobile w/ Wheels

Instruction Manual

Содержание IND-SFC Series

Страница 1: ...IND SFC Series Larson Electronics LLC Phone 877 348 9680 Fax 903 498 3364 www larsonelectronics com Solid state Frequency Converter Mobile w Wheels Instruction Manual ...

Страница 2: ... an appropriate configuration and cable diameter Do not overload the frequency converter to prevent the electric shock or cause fires Please follow all applicable local and national electrical and building code In case of abnormal phenomenon happens follow this user manual in troubleshooting or contact the manufacturer Please keep frequency converter clean and do not put heavy objects on top of it...

Страница 3: ...WM technology enhances compact size low noise and high reliability Capable to simulate global voltage frequency power supplies Frequency converters are equipped with electronic circuit instant trip breaker buzzer alarm for over voltage over current over temperature output short circuit protection Checklist Every frequency converter has functional testing before leaving factory the frequency conver...

Страница 4: ...utput Air switch Input Terminals Output Terminals Low High Voltage Switch For 30kVA and Above Low High Voltage Indicator For 3 Phase 3kVA to 20kVA Phase Line Voltage Switch For 3 Phase 3kVA to 20kVA Larson Electronics LLC Phone 877 348 9680 Fax 903 498 3364 www larsonelectronics com ...

Страница 5: ...or components are sensitive to static electricity be careful in touching the metal control panel Larson Electronics LLC Phone 877 348 9680 Fax 903 498 3364 www larsonelectronics com Grounding System In addition to safety consideration well grounded system also can avoid the power system interferes equipment normal operation Ground Cable should be separated with Neutral Cable unless special applica...

Страница 6: ...77 348 9680 Fax 903 498 3364 www larsonelectronics com 3Ø 4W 380V 1Ø 2W 0 300V Capacity Input Max O P Current Output R R S T N G ow Hi Low L L N G 10kVA 4mm2 6mm2 83 2A 41 6A 16mm2 10mm2 15kVA 6mm2 6mm2 125A 62 5A 25mm2 10mm2 20kVA 6mm2 6mm2 166 6A 83 3A 35mm2 10mm2 30kVA 10mm2 10mm2 250A 125A 50mm2 10mm2 45kVA 16mm2 10mm2 375A 187 5A 75mm2 10mm2 50kVA 16mm2 10mm2 416 6A 208 3A 83mm2 10mm2 60kVA 2...

Страница 7: ... 30mm2 10mm2 208 3A 104 2A 42mm2 10mm2 90kVA 35mm2 10mm2 250A 125A 50mm2 10mm2 100kVA 50mm2 10mm2 277 7A 138 8A 70mm2 10mm2 120kVA 70mm2 10mm2 333 3A 166 6A 95mm2 10mm2 150kVA 95mm2 10mm2 416 6A 208 3A 120mm2 10mm2 200kVA 120mm2 10mm2 555 5A 277 7A 185mm2 10mm2 300kVA 180mm2 10mm2 833 3A 416 6A 240mm2 10mm2 IND SFC Series Larson Electronics LLC Phone 877 348 9680 Fax 903 498 3364 www larsonelectro...

Страница 8: ...ingle Phase Output Three Phase Input Three Phase Output T R S N G U V W N G Input R S T N G L N G L N G L N G Wiring Terminals Output Input Output Input Output IND SFC Series Larson Electronics LLC Phone 877 348 9680 Fax 903 498 3364 www larsonelectronics com ...

Страница 9: ...IND SFC Series Larson Electronics LLC Phone 877 348 9680 Fax 903 498 3364 www larsonelectronics com Chapter V Operation Panel Some models may differ slightly in layout ...

Страница 10: ...change 0 150V low and 1 300V high base on required voltage 6 Press to POWER ON switch ON 7 Connect loads cable and turn on the AC OUTPUT switch to obtain required standard AC power supplies 8 Frequency converter has overcurrent overload over temperature short circuit instantaneous power off protection and warning indicators In case of above phenomenon happens the protection circuit cut off output ...

Страница 11: ...20 8A 41 6A 62 5A 83 3A Load stabilization Rate 1 Frequency Stability 0 01 Harmonic Distortion Pure Sine Wave 2 Frequency meter 4 digit digital frequency meter resolution 0 1Hz Step Voltmeter 4 digit digital voltage meter resolution 0 1V Ammeter 4 digit digital ammeter resolution 0 1A Watt meter 4 digit digital Watt meter resolution 0 1W Protection With overload short circuit over temperature Inst...

Страница 12: ...00V High Voltage range Frequency 40 0Hz to 120Hz Higher than 120Hz is customized Current Low grade 83 2A 125A 166 6A 250A 375A 416 6A 500A High grade 41 6A 62 5A 83 3A 125A 187 5A 208 3A 250A Load stabilization Rate 1 Frequency Stability 0 01 Harmonic Distortion Pure Sine Wave 2 Frequency meter 4 digit digital frequency meter resolution 0 1Hz Step Voltmeter 4 digit digital voltage meter resolution...

Страница 13: ...z is customized Current Low grade 625A 750A 833 3A 1000A 1250A High grade 312 5A 375A 416 6A 500A 625A Load stabilization Rate 1 Frequency Stability 0 01 Harmonic Distortion Pure Sine Wave 2 Frequency meter 4 digit digital frequency meter resolution 0 1Hz Step Voltmeter 4 digit digital voltage meter resolution 0 1V Ammeter 4 digit digital ammeter resolution 0 1A Protection With overload short circ...

Страница 14: ...4A 27 6A 41 6A 55 6A 83 2A 125A 166 6A High grade 4 2A 13 8A 20 8A 27 8A 41 6A 62 5A 83 3A Load stabilization Rate 1 Frequency Stability 0 01 Harmonic Distortion Pure Sine Wave 2 Frequency meter 4 digit digital frequency meter resolution 0 1Hz Step Voltmeter 4 digit digital voltage meter resolution 0 1V Ammeter 4 digit digital ammeter resolution 0 1A Watt meter 4 digit digital Watt meter resolutio...

Страница 15: ... 3A 277 7A 333 3A 416 6A 555 5A 833 3A High grade 104 2A 138 8A 166 7A 208 3A 277 7A 416 6A Load stabilization Rate 1 Frequency Stability 0 01 Harmonic Distortion Pure Sine Wave 2 Frequency meter 4 digit digital frequency meter resolution 0 1Hz Step Voltmeter 4 digit digital voltage meter resolution 0 1V Ammeter 4 digit digital ammeter resolution 0 1A Watt meter 4 digit digital Watt meter resoluti...

Страница 16: ...pacity of the frequency converter No output voltage 1 Is he fuse burn down or not 2 Is t overloaded 1 heck the fuse and replace the fuse with same specification if necessary 2 eplace a larger capacity frequency converter Voltmeter ammeter and power show 0 when the output frequency is normal 1 Turn the power switch to OFF position 2 hange output voltage switch to zero 3 Turn the power switch to ON ...

Страница 17: ...torage The environment of the frequency converter being placed has direct affect to its function and lifetime the environment should follow the conditions Moving Please shut down and disconnect all cables before moving the frequency converter Do not move the frequency converter upside down Handle the frequency converter with care in moving to avoid impact Placement Do not put the frequency convert...