60W Escalator Handrail UV Sanitizer

(3)

 

UVC Lamps - 200ft/min Capacity - Stainless Steel

Instruction Manual

Thank you for your purchase of the Larson Electronics

 IND-HR-UVC-EXS-R1-24-3L-120V-2X

.

EPA Reg. No 98409-1

EPA Est. No. 98409-TX-1

WARNING: 

READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE. 

CRITICAL SAFETY INSTRUCTIONS: 

INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY

RELEVANT LOCAL BUILDING CODES.

RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF 

FIXTURE'S

 ELECTRICAL

SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.

BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.

MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE

 FIXTURE'S

 RATED VOLTAGE.

TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP

OBJECTS. SUITABLE FOR DAMP LOCATIONS.

IMPORTANT

 

READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE 

REFERENCE.  THE 

IND-HR-UVC-EXS-R1-24-3L-120V-2X

  MUST  BE  WIRED  IN  ACCORDANCE  WITH  NATIONAL 

ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.  

WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS 

PRODUCT. IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT  OF THIS INSTRUCTION SHEET, 

CONSULT AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE. 

WARNING:

 

MAKE SURE POWER IS TURNED 

OFF

 BEFORE STARTING THE 

INSTALLATION OR PERFORMING ANY MAINTENANCE.

 

 

RISK OF FIRE/ELECTRIC SHOCK –

 

DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.

 

RISK OF PERSONAL INJURY –

 

FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY. 

RISK OF BURN –

 

ALLOW FIXTURE TO COOL BEFORE SERVICING. 

WARNING: 

ULTRAVIOLET LIGHT IS HARMFUL TO EYES AND SKIN. DO NOT STARE DIRECTLY INTO THE 

ULTRAVIOLET BEAM WITHOUT WEARING PROTECTIVE GEAR TO PROTECT EYES FROM LONG TERM DAMAGE. 

UNPLUG LAMP BEFORE SERVICING

.

The Larson Electronics IND-HR-UVC-EXS-R1-24-3L-120V-2X is an Escalator Handrail UV Sanitizer for 

busy locations and occupied areas. This 60-watt unit has three UV fluorescent lamps that provide 

germicidal UV-C output at a range of 280 nm - 200 nm (254 nm peak). Capable of sanitizing handrails of 

escalators and power walks that operate up to 200ft/min, the UV disinfection device is protected by a 

stainless steel enclosure. This sanitizer mounts on the exterior base of handrails, which offers peace of 

mind and confidence for people in the occupied area.

MOUNTING

The IND-HR-UVC-EXS-R1-24-3L-120V-2X mounts directly on the exterior base of the escalator handrail. 

This exterior mounting solution provides confidence for people using the escalator or power walk, knowing 

that the handrail is constantly being sanitized.

VOLTAGE

The handrail sanitizer operates on 120V AC.