IND-AHF-CD-UVC-R1-
2
20V-50C
120W Spare/Replacement UV Fluorescent Bulb for Germicidal Lights
48" UV-C
Instruction
Manual
Thank you for your purchase of the Larson Electronics
IND-AHF-CD-UVC-R1-
2
20V-50C
.
EPA Reg. No 98409-1
EPA Est. No. 98409-TX-1
WARNING:
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
CRITICAL SAFETY INSTRUCTIONS:
•
INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY
RELEVANT LOCAL BUILDING CODES.
•
RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF LUMINAIRES ELECTRICAL
SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.
•
BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.
•
MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE RATED LUMINAIRE FIXTURES VOLTAGE.
•
TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP
OBJECTS.
•
WARNING:
ULTRAVIOLET LIGHT IS HARMFUL TO EYES AND SKIN. DO NOT STARE DIRECTLY INTO THE
ULTRAVIOLET BEAM WITHOUT WEARING PROTECTIVE GEAR TO PROTECT EYES FROM LONG TERM DAMAGE.
UNPLUG LAMP BEFORE SERVICING.
•
NOTE:
DO NOT TOUCH THE BULB WITH BARE HANDS. THE OILS IN YOUR SKIN WILL DAMAGE THE LAMP.
FINGERPRINTS WILL RESULT IN REDUCED PERFORMANCE AND SIGNIFICANTLY REDUCE THE LIFESPAN OF THE
LAMP UNLESS THEY ARE REMOVED WITH ALCOHOL.
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
1
of
3
WARNING:
ULTRAVIOLET LIGHT IS HARMFUL TO EYES AND SKIN. DO NOT STARE DIRECTLY INTO THE
ULTRAVIOLET BEAM WITHOUT WEARING PROTECTIVE GEAR TO PROTECT EYES FROM LONG TERM DAMAGE.
UNPLUG LAMP BEFORE SERVICING.
The IND-AHF-CD-UVC-R1-
2
20V-50C Mobile UV Air Sanitation Purifier from Larson Electronics actively disinfects the surrounding air in
occupied areas without noise. This unit uses eight lamps that provide 212.8W total UVC output during sanitation. Designed for portable
applications, the stainless steel system has four wheels at the base for seamless deployment, transportation and storage.
OPERATION
Surrounding "dirty" air is drawn into the portable UV purifier via disposable filters at the base of the system. The "dirty" air
passes through the UV sanitation chamber where it is treated with UVC light using the eight fluorescent lamps. The
disinfection process kills up to 99.9% of viruses, bacteria, mold, spores and other harmful microbes. Clean sanitized air
exits the chamber through a louvered exhaust panel and is released back into the environment. The louvers also protect
people from UV exposure in the surrounding area. This low-maintenance air disinfection process is continuous and quiet.
MOUNTING
The IND-AHF-CD-UVC-R1-
2
20V-50C has four mobile wheels at the base for portable deployment in occupied areas. This
mobile solution ensures the UV air purifier is easily setup, transported and stored when needed.
WIRING/PLUG
This unit is equipped with 50 feet of 16/3 chemical and abrasion resistant SOOW cord that is fitted with an industrial grade
cord cap for easy connection to common wall outlets.
Plug options include standard NEMA 6-15 15 amp straight blade
plug, standard NEMA 6-20 20 amp straight blade plug, NEMA L6-15 15 amp twist lock plug, NEMA L6-20 20 amp twist lock
plug, a two pin 16 amp rated Schuko plug (Type F, CEE 7/4 plug) with ground contact and socket for European outlets up to
250V, or a BS546 (Type M
)
, CEE 3-pin 15 amp rated plug for Indian and South African outlets. Alternatively, we can provide
flying leads with no plug for hard wire applications or for operators who prefer to wire in user provided cord caps. Please
choose pigtail option below for flying leads with no plug.