background image

HALS

-EMG

-48-2L-LED 

Larson Electronics, LLC

 

  Phone: (800) 369-6671 

 Fax: (903) 498-3364 

 www.larsonelectronics.com 

1

 of 

2

 

Hazardous Location LED Lighting 

4' 2 Lamp Fixture - LED Bulb - Multi-voltage - C1D2 & C2D2 

Instruction Manual 

Thank you for your purchase of the Larson Electronics HALS-48-2L-LED Hazardous Location LED Light. Please follow 
the steps below in order to operate and maintain this product. 

WARNING! 

1.

TO  PREVENT  RISK  OF  ELECTRICAL  SHOCK  DEACTIVATE/DISCONNECT  POWER  SUPPLY  BEFORE
INSTALLING, MAINTAINING OR RELAMPING FIXTURE.

2.

DO  NOT  INSTALL  WHERE  THE  MARKED  OPERATING  TEMPERATURE  EXCEEDS  THE  IGNITION
TEMPERATURE OF THE HAZARDOUS ATMOSPHERE(S). KEEP TIGHTLY CLOSED WHEN IN OPERATION.

3.

THIS  FIXTURE  SHOULD  BE  INSTALLED  BY  QUALIFIED  TECHNICIANS  IN  STRICT  ACCORDANCE  WITH  THE
NATIONAL ELECTRICAL CODE AND ANY LOCAL REQUIREMENTS.

INSTALLATION 

This fixture can be installed directly to any flat surface using the mounting brackets provided. For installation on structural 
members like beams, angles or channels, it may be necessary to install beam clamps on the mounting brackets.

1.

Install fixture to mounting surface at mounting locations (mounting hardware not included).

2.

For supply connection, use wire suitable for at least 90°C

3.

Connect black lead to the incoming line lead, white lead to incoming neutral and green lead to incoming ground lead.

Voltage must match product label!

4.

Use the wiring diagram printed on the ballast label for reference.

To change lamp, release latches to remove front lens from fixture. Keep hold of lens when removing! 

Remove old lamps and replace with compatible lamps matching fixture ratings. Tighten latches. 

MAINTENANCE 

Electrical and mechanical inspection of all components must be performed on a regularly scheduled basic, determined by 
the environment and frequency of use. It is recommended that inspection be performed a minimum of once a year. 

WARNING: 

ELECTRICAL POWER SUPPLY MUST BE “OFF” BEFORE AND DURING INSTALLATION AND 

MAINTENANCE. INSTALLATION AND MAINTENANCE PROCEDURE MUST BE PERFORMED BY A TRAINED AND 
COMPETENT ELECTRICIAN.

 

1.

Inspect  all  contact  wire  terminals  for  tightness.  Discoloration  due  to  excessive  heat  is  an  indicator  of  a  possible
problem and should be thoroughly investigated and repaired as necessary.

2.

Inspect contacts for signs of wear and replace if necessary.

3.

Clean exterior surfaces making sure nameplates remain legible.

If  any  part  of  the  light  appears  to  be  missing,  broken,  or  show  signs  of  damage

—discontinue  use  immediately!  This 

condition  could  cause  serious  or  fatal  personal  injury  due  to  electrocution  and/or  equipment  damage.  Repair  with  the 
proper replacement part(s) before continuing service. 

TROUBLESHOOTING 

Refer to the guide below or contact the manufacturer if the fixture does not function properly. 

Is the correct line voltage being supplied to the fixture?

Is the fixture properly grounded?

These instructions may not cover all details or variations of this product for your equipment or installation requirements. 
Should further information not covered by these instructions be required, please contact Larson Electronics at 1-800-369-
6671 for further assistance. 

Please visit LarsonElectronics.com for 

Warranty

 and 

Return

 information.

 

Отзывы: