11  FAQ 

What is ETHERLINE

®

 GUARD? 

ETHERLINE

®

 GUARD is a stationary monitoring device that evaluates the current status of a data line 

and indicates it as a percentage. This is based on data determined from the physical properties of the 
data transmission. 

 

What exactly is the determined "cable condition"? 

The real-time display of the cable condition makes it possible to recognise the wear limit of a cable and to 
plan the optimal replacement time in advance. 

It is a value for the performance condition of the cable 

determined from several measured variables. This is indicated in 100% to 20%; below 20%, reliable 
conclusions about the functionality of the cable are no longer possible.  

How does the measurement of the condition of the pipe work? 

The output of the "cable status" is based on an algorithm which collects, converts and continuously 
evaluates measured values from various physical transmission parameters as raw values. The raw 
values consist, for example, of protocol-related transmission parameters and/or a quality indicator, which 
can be calculated from a statistic of the level values. 

The "user data" (data transmission) are neither influenced nor evaluated. If a teach-in is carried out, the 
line is calibrated, and limit values are set according to the parameters. If these limit values are violated 
during operation, correction values flow into the algorithm. 

It is important that the algorithm includes historical values. This leads to the following consequence: If a 
line is subjected to such mechanical stress (far above the specifications) that it cannot physically "age", 
the "prediction" may be delayed. Example: if the data cable is cut with a side cutter, the cable "ages" 
abruptly; logically, no "prediction" can take place in advance. 

What exactly does the "cable status" say? 

The "cable status" is a quality value of the transmission properties of the data line on the GUARD DATA 
socket including the connectors. The classification of the areas is based on the model of a traffic light: 
Green area = cable / transmission properties are OK. Yellow area = maintenance/replacement required. 
Red area = line defective. 

How do customers benefit from using ETHERLINE

®

 GUARD? 

In highly dynamic, demanding movements with high speeds and strong torsion, it is advantageous and 
cost-saving if the connection systems are monitored to avoid unforeseen downtimes and thus an 
impairment of productivity. ETHERLINE

®

 GUARD determines the condition of a data line and indicates 

the performance in percent. If the performance falls below a certain value, the device sounds an alarm 
and the line must be checked or replaced if necessary. 

 

What can ETHERLINE

®

 GUARD do? 

ETHERLINE

®

 GUARD determines the current performance of a data line from various measured 

variables and indicates this as a percentage. 

The scope of analysis of ETHERLINE

® 

 GUARD is 

deliberately reduced and monitors a data line and indicates its functionality. This makes it possible to 
better plan maintenance work. 

For which industry is ETHERLINE

®

 GUARD suitable? 

ETHERLINE

®

 GUARD can be used wherever data cables are used. Especially in moving applications 

with high speeds and strong torsion. Such applications are often found in (intra-)logistics, the automotive 
sector and medical technology. In principle, however, it is suitable for a wide range of industries. 

 

 

Содержание ETHERLINE GUARD PM03T

Страница 1: ...65 Stuttgart Germany Phone 49 711 78 38 01 Fax 49 711 78 38 26 40 info lapp de www lappkabel de ETHERLINE GUARD PM03T PM02TWA Operating instructions Issue 1 0 11 04 2022 from firmware V 1 00 Link to t...

Страница 2: ...and ideas Furthermore we offer to send the complete corresponding source code of the respective open source software to you and any third party as a DVD upon your request for a contribution towards co...

Страница 3: ...ecycling and disposal WEEE 9 2 Security recommendations 10 3 Overview 11 4 Structure and connection of the ETHERLINE GUARD 12 4 1 Connection of the power supply 13 4 2 Connection of the line to be mon...

Страница 4: ...le status via MQTT 25 9 Firmware update 26 10 Reset to factory setting 27 11 FAQ 28 12 Technical data 31 12 1 ETHERLINE GUARD with LAN connection 31 12 2 ETHERLINE GUARD with WIFI connection 32 12 3 D...

Страница 5: ...ns point out possible dangers and give advice on how to avoid dangerous situations 1 2 Signs and signal words If the danger notice is not observed there is an immediate danger to the health and life o...

Страница 6: ...ts described complies with all safety requirements including all applicable laws regulations provisions and standards The minimum length of the Ethernet cable to be monitored is 2m Before using the un...

Страница 7: ...rol unit the product or environmental damage Only use the unit as intended 1 6 Assembly Disassembly 1 6 1 Access restriction The assemblies are open equipment and may only be installed in electrical o...

Страница 8: ...at any time and without notice No claims for changes to products already supplied can be made on the basis of the information illustrations and descriptions in this documentation In addition to the in...

Страница 9: ...ective 2012 19 EU for the disposal of waste electrical and electronic equipment The electrical appliances described are designed for the business to business B2B sector and are to be recycled Accordin...

Страница 10: ...ponents to qualified personnel Security of the software Keep the firmware and all communication components up to date at all times Check regularly for firmware updates for the product Only activate pr...

Страница 11: ...on For monitoring the service life of a data line at risk of failure e g function critical data line in dynamic or mechanically loaded applications Suitable for data lines according to transmission st...

Страница 12: ...cable to be monitored and a LAN connection PM03T or an antenna connection for WiFi PM02TWA configuration via the web interface The LEDs on the left edge of the housing indicate the status of the unit...

Страница 13: ...he requirements for limited energy circuits according to UL61010 1 4 2 Connection of the line to be monitored DATA The ETHERLINE GUARD has two RJ45 connections DATA for the link to be monitored whereb...

Страница 14: ...in chapter 12 2 4 4 Connection of the digital outputs Q1 Q2 The digital outputs Q1 and Q2 are only active after the teach in has been completed The digital output Q1 can signalize that maintenance is...

Страница 15: ...the unit The measurement recordings can be used by the LAPP Support to analyse the unit If there is an SD card in the unit the cable readings are automatically stored there Logging off Only the cable...

Страница 16: ...ess please press the SET button for at least 20s As soon as the PWR LED and the STATUS LED both light up red simultaneously release the SET button again after 20s Teach in PWR and STATUS light up perm...

Страница 17: ...1Hz Device is trying to establish a connection to an access point o Blue and green alternately every 3s Access point and client active If an error occurs during the teach in process the PWR LED flash...

Страница 18: ...sful teach in or if there was a power failure the measurement requires a few seconds until a measured value is available again This is indicated after the restart by a green flashing STATUS LED initia...

Страница 19: ...1 with subnet mask 255 255 255 0 for LAN access Open the website in a current browser with https 192 168 0 32 For security reasons the web interface can only be accessed via a secure HTTPS connection...

Страница 20: ...on the initial situation The LEDs switch off after releasing the set button the selected function is executed 6 3 Initial registration When logging in for the first time you will be asked to set a pa...

Страница 21: ...tus Status of the monitored data line 100 is the initial state Lower values indicate a deterioration of the cable status Link status Connection status of the line to the network controller upper DATA...

Страница 22: ...is used for this purpose This cannot be authenticated by the browser the confirmation of the identity of the device is not possible for the browser To enable this the ETHERLINE GUARD can be provided...

Страница 23: ...ed the connection to the WLAN network of the ETHERLINE GUARD the web interface can be accessed in the browser at https 192 168 4 1 For security reasons the web interface can only be accessed via a sec...

Страница 24: ...ess point of the company network In client mode the ETHERLINE GUARD must still be told which WiFi network or access point it should connect to and which IP settings it should use in the WiFi network T...

Страница 25: ...r can be specified in Broker address and Broker port MQTT also enables TLS SSL encryption of the transmission For this a certificate for the broker Certificate and the certificate Client certificate a...

Страница 26: ...the firmware stored on the PC can be selected for update The ETHERLINE GUARD saves the firmware file in its internal memory After restarting the device the firmware is checked If the content is corre...

Страница 27: ...R LED flashes alternately red green Now release the SET button The factory reset is now carried out and the ETHERLINE GUARD is restarted Disconnect the appliance from the mains SET while holding down...

Страница 28: ...ove the specifications that it cannot physically age the prediction may be delayed Example if the data cable is cut with a side cutter the cable ages abruptly logically no prediction can take place in...

Страница 29: ...bles Can ETHERLINE GUARD qualify cables from competitors No the ETHERLINE GUARD cannot perform cable qualification by recording standardised measured variables It also does not recognise whether it is...

Страница 30: ...nts as well as the level of expected costs in the event of a production stoppage and much more It also depends on the respective scenario in which the customer operates the goods produced as well as t...

Страница 31: ...ber and type of outputs 2 max 0 2 A PWM frequency 24 Hz PWM duty cycle 0 99 0 Protection against overload and short circuit Yes Status display 3 LEDs Power Status COM Power supply DC 24 V 18 30 V DC P...

Страница 32: ...n RJ45 sockets Transmission rate 100 Mbit s Delay at 100 Mbit s 735 ns Outputs Q1 Q2 Signal voltage at the output 24 V DC Number and type of outputs 2 max 0 2 A PWM frequency 24 Hz PWM duty cycle 0 99...

Страница 33: ...ETHERLINE GUARD Issue 1e 11 04 2022 33 12 3 Dimensioned drawing 12 3 1 PM03T 12 3 2 PM02TWA...

Отзывы: