QS
MODEL
P06012000
www.lanzini.it
D
EN
INSTRUCTIONS
INSTALLATION, USE AND MAINTENANCE
-
Warning!
Security of the fitting is guaranteed only with the appropriate use of the
following instructions: therefore it is necessary to preserve them.
-
Warning!
Before connecting to the main network, during assembly or
replacement of the product, make sure to disconnect the tension.
-
Warning!
The product has to be repaired only by professional technicians or by the
manufacturer.
- During product installation respect carefully the plant rules.
- The fitting should be used only if complete with its protection screen; it is lens in
policarbonate.
- In case of cracks or damages the screen should be immediately replaced.
- For any replacement contact the manufacturing company.
- The fitting must be installed by a professional electrician.
- The fitting cannot be modified or tampered with in any way, any modification may
compromise security by making it dangerous. The manufacturer declines any
responsibility for the modified products. Class I fitting must be connected to the
ground circuit of the electrical plant.
- Keep at least 1 m between the fitting and the illuminated surface.
- Fitting suitable for outdoor applications. Protection degree IP66.
- Fitting suitable for direct mounting on normally inflammable surfaces.
- Remove the wall mounting flange by unscrewing the n° 2 side screws.
- Install the wall fixing flange using n°2/3 fischer, with a minimum diameter of 6 mm.
- Make sure that the fixing flange is securely connected to the wall (fig. A).
- Connect the power cables to a triple connector that can guarantee a minimum
protection degree IP67 (fig.B). Lanzini provides this connector (code
LKITA00000000003) as a separate mounting kit, on request; alternatively, you can
use a similar connector. The fitting is supplied with a cable looped and pulled. You
can connect it to the network using a connection system that guarantees the IP 67 or
higher (IP box, etc.).
- Position the fitting with the required inclination and tighten the screws previously
removed (fig. C).
- Make sure you have done everything correctly and reconnect the tension (fig. D).
-
Warning!
Risk of electric shock
- For use in environments where an accumulation of non-conductive dust on the
luminaire
1 m
Power supply:
230 V AC - 50 HZ
Insulation class:
I
Operating temperature:
-40° +45°C
Power Weight Dimensions
Surface exposed to the wind
10W
0,7 Kg
171×155×32 mm
0,018 m²
0,0041 m²
20W
0,7 Kg
171×155×32 mm
0,018 m²
0,0041 m²
IP66
OUTDOOR
EP s.p.a. Via del Commercio 1 - 25039 - Travagliato (BS) - ITALY
IT
-Questo prodotto contiene una sorgente luminosa di efficienza energetica classe
EN
-This product contains a light source of energy efficiency class