6: Configuration Using Telnet/Serial Port (Setup Mode)
XPress™ DR+ Industrial Device Server User Guide
48
Figure 6-1. MAC Address
*** Lantronix XPress DR+ Industrial Device Server ***
MAC address 0080A38E3C7A
Software version V6.11.0.4 (160916)
Press Enter for Setup Mode
Model: Device Server Plus+! (Firmware Code:rA
3. To enter Setup Mode,
press Enter within 5 seconds
. The current configuration settings
display, followed by the Change Setup menu.
Figure 6-2. Setup Menu Options
Change Setup:
0 Server
1 Channel 1
2 Channel 2
5 Expert
6 Security
7 Defaults
8 Exit without save
9 Save and exit Your choice ?
4. Select an option on the menu by entering the number of the option in the
Your choice
?
field and pressing
Enter
.
5. To enter a value for a parameter, type the value and press
Enter
, or to confirm a current
value, just press
Enter
.
6. When finished, save the new configuration (option 9). The unit exits and reboots.
Serial Port Connection
To configure the unit through a serial connection:
1. Connect a console terminal (VT100) or PC running a terminal emulation program from
port 1 with the Lantronix supplied P/N: 500-103-R RJ45-to-DB9F serial cable.
2. The default serial port settings are 9600 baud, 8 bits, no parity, 1-stop bit, no-flow
control.
Note:
Reset the XPress DR+ unit by cycling the unit's power (turning the power off and
back on). Immediately upon resetting the device, hold down the
x
key at the terminal (or
emulation) while resetting the unit.
You must do this within three seconds of resetting
the unit
.
3. At this point, the screen display is the same as when you use a Telnet connection. To
continue, go to
step 3 in
Telnet Connection
above.