F: Binary to Hex Conversion
XPress™ DR Industrial Device Server User Guide
105
SERIAL TO NETWORK
Clear input buffer upon:
NETWORK TO SERIAL
Clear output buffer upon:
Alternate Packing Algorithm
Hex
Passive connection
Disconnect
Active connection
Passive connection
Disconnect
Enable
E7
Active connection
Passive connection
Disconnect
Active connection
Passive connection
Disconnect
Enable
F7
Interface Mode Options
Table F-6 Interface Mode Options
Interface
Bits
Parity
Stop Bits
Hex
RS-232C
7
No
1
48
RS-232C
7
No
2
C8
RS-232C
7
Even
1
78
RS-232C
7
Even
2
F8
RS-232C
7
Odd
1
58
RS-232C
7
Odd
2
D8
RS-232C
8
No
1
4C
RS-232C
8
No
2
CC
RS-232C
8
Even
1
7C
RS-232C
8
Even
2
FC
RS-232C
8
Odd
1
5C
RS-232C
8
Odd
2
DC
RS-422/485
7
No
1
49
RS-422/485
7
No
2
C9
RS-422/485
7
Even
1
79
RS-422/485
7
Even
2
F9
RS-422/485
7
Odd
1
59
RS-422/485
7
Odd
2
D9
RS-422/485
8
No
1
4D
RS-422/485
8
No
2
CD
RS-422/485
8
Even
1
7D
RS-422/485
8
Even
2
FD
RS-422/485
8
Odd
1
5D
RS-422/485
8
Odd
2
DD
RS-422/485 2-Wire
7
No
1
4B
RS-422/485 2-Wire
7
No
2
CB
RS-422/485 2-Wire
7
Even
1
7B
RS-422/485 2-Wire
7
Even
2
FB
RS-422/485 2-Wire
7
Odd
1
5B
RS-422/485 2-Wire
7
Odd
2
DB
RS-422/485 2-Wire
8
No
1
4F