SM24TBT2DPA and SM24TBT2DPB Web User Guide
Read Community:
Indicates the community read access string to permit access to SNMP agent.
The allowed string length is 0 to 255, and the allowed content is the ASCII characters 33-126.
The field is applicable only when SNMP version is SNMPv1 or SNMPv2c. If SNMP version is SNMPv3, the
community string will be associated with SNMPv3 communities table. It provides more flexibility to
configure security name than a SNMPv1 or SNMPv2c community string. In addition to community string, a
particular range of source addresses can be used to restrict source subnet.
Write Community:
Indicates the community write access string to permit access to SNMP agent.
The allowed string length is 0 to 255, and the allowed content is the ASCII characters 33-126.
The field is applicable only when SNMP version is SNMPv1 or SNMPv2c. If SNMP version is SNMPv3, the
community string will be associated with SNMPv3 communities table. It provides more flexibility to
configure security name than a SNMPv1 or SNMPv2c community string. In addition to community string, a
particular range of source addresses can be used to restrict source subnet.
Engine ID:
Indicates the SNMPv3 engine ID. The string must contain an even number (in hexadecimal
format) with the number of digits between 10 and 64, but all-zeros and all-'F's are not allowed. Change of
the Engine ID will clear all original local users.
Buttons
:
Apply
– Click to save changes.
Reset -
Click to undo any changes made locally and revert to previously saved values.