Chapter 5 - Maintenance
This chapter describes the switch Maintenance configuration tasks, including Restart
Device, Reboot Schedule, Factory Defaults, Firmware Upgrade, Configuration, and
Server Report.
5-1 Restart Device
You can restart the on this page. After restart, the switch will boot normally. To Restart
the switch in the web UI:
1. Click Maintenance, Restart Device.
2. Check or uncheck the Always On PoE checkbox as desired.
3. At the “
Are you sure..?
” prompt, select an option if desired, and then click Yes.
Figure 5-1: Restart Device page
Parameter descriptions:
Note
: SM24TBT2DPA FW v6.54.3104 removed the Force Cool Restart checkbox from this page.
Always On PoE
: If you check this button, during switch warm restart, it will continue providing PoE power
to the PDs.
Note 1:
It will take 75 - 80 seconds to have PoE++ power on the ports to power PDs again if
the switch makes a cold restart. The "Always on PoE" feature has no effect on this time.
Note 2:
The “Ultra-fast PoE” feature improves PoE startup time; it provides PoE output to attached PDs
within five seconds after a cold start
.
Buttons:
Yes
: Click to restart the device.
No:
Click to return to the Port State page without restarting.
Wait while the Restart occurs:
Wait a couple of minutes. If necessary, refresh the Browser and log back in to the switch.