SM24TBT2DPA and SM24TBT2DPB Web User Guide
3-5.4.1.3 Alarm
This page displays an overview of RMON Alarm entries. Each page shows up to 99 entries from the Alarm
table, default being 20, selected through the "entries per page" input field. When first visited, the web page
will show the first 20 entries from the beginning of the Alarm table. The first displayed will be the one with
the lowest ID found in the Alarm table.
The "Start from Control Index" lets you select the starting point in the Alarm table.
Clicking the Refresh button will update the displayed table starting from that or the next closest Alarm table
match.
The Last Entry (>>) button will use the last entry of the currently displayed entry as a basis for the next
lookup. When the end is reached the text "
No more entries
" is shown in the displayed table. Use the
<<
button to start over.
Web Interface
To monitor an RMON Alarm Overview in the web interface:
1. Click Monitor, Security, Switch, RMON, Alarm.
2. Check “Auto-refresh”.
3. Click “Refresh” to refresh the port detailed statistics.
Figure 3-5.4.1.3: RMON Alarm Overview page
Parameter descriptions:
ID:
Indicates the index of Alarm control entry.
Interval:
Indicates the interval in seconds for sampling and comparing the rising and falling threshold.
Variable:
Indicates the particular variable to be sampled
Sample Type:
The method of sampling the selected variable and calculating the value to be compared
against the thresholds.
Value:
The value of the statistic during the last sampling period.
Startup Alarm:
The alarm that may be sent when this entry is first set to valid.
Rising Threshold:
Rising threshold value.
Rising Index:
Rising event index.
Falling Threshold:
Falling threshold value.
Falling Index:
Falling event index.