Lantronix
SM24TBT2DPA and SM24TBT2DPB Web User Guide
GVRP protocol timers
:
Join-time
is a value in the range 1-20 in units of centi seconds (i.e., in units of one hundredth of a
second). The default is 20 cs.
Leave-time
is a value in the range 60-300 in units of centi seconds (i.e., in units of one hundredth of
a second). The default is 60 cs.
Leave All-time
is a value in the range 1000-5000 in units of centi seconds (i.e., in units of one
hundredth of a second). The default is 1000 cs.
Max VLANs
: When GVRP is enabled a maximum number of VLANs supported by GVRP is specified. By
default, this number is 20 VLANs. This number can only be changed when GVRP is disabled globally.
Buttons:
Apply
– Click to save changes.
Reset -