2- 13.2 Power Delay
The PoE Power Delay page lets you set the delay time of power provided after the device is rebooted.
To configure Power over Ethernet delay in the web UI:
1. Click Configuration, PoE, Power Delay.
2. At the Delay Mode dropdown, enable the delay mode to delay power to the device after a reboot.
3. Specify the power providing delay time after a reboot occurs.
4. Click Apply to apply the change.
Figure 2-13.2: PoE Power Delay page
Parameter descriptions:
Port
: This is the logical port number for this row.
Delay Mode
: Turn on / off the power delay function.
Enabled
: Enable POE Power Delay.
Disabled
: Disable POE Power Delay.
Delay Time(0~300sec)
: When rebooting, the PoE port will start to provide power to the PD when it is out
of delay time. The default is 0 seconds; the valid range is 0-300 seconds.
Buttons
:
Apply
– Click to save changes.
Reset -
Click to undo any changes made locally and revert to previously saved values.