Lantronix
SM24TBT2DPA and SM24TBT2DPB Web User Guide
Maximum Hop Count:
This defines the initial value of remaining Hops for MSTI information generated at
the boundary of an MSTI region. It defines how many bridges a root bridge can distribute its BPDU
information to. Valid values are in the range 6 to 40 hops.
Transmit Hold Count:
The number of BPDU's a bridge port can send per second. When exceeded,
transmission of the next BPDU will be delayed. Valid values are in the range 1 to 10 BPDU's per second.
Advanced Settings
Edge Port BPDU Filtering:
Control whether a port explicitly configured as Edge will transmit and receive
BPDUs.
Edge Port BPDU Guard:
Control whether a port explicitly configured as Edge will disable itself upon
reception of a BPDU. The port will enter the error-disabled state and will be removed from the active
topology.
Port Error Recovery:
Control whether a port in the error-disabled state automatically will be enabled after
a certain time. If recovery is not enabled, ports have to be disabled and re-enabled for normal STP
operation. The condition is also cleared by a system reboot.
Port Error Recovery Timeout:
The time to pass before a port in the error-disabled state can be enabled.
Valid values are 30 - 86400 seconds (24 hours).
Buttons
Apply
– Click to save changes.
Reset -
Click to undo any changes made locally and revert to previously saved values.