Storm Control
This page lets you configure switch Storm control parameters. There is a destination lookup failure storm rate
control, multicast storm rate control, and a broadcast storm rate control. These only affect flooded frames, i.e.,
frames with a (VLAN ID, DMAC) pair not present in the MAC Address table. The configuration indicates the
permitted packet rate for unicast, multicast, or broadcast traffic across the switch
Web Interface
To configure Storm Control parameters in the web UI:
1.
Click Quality of Service and Storm Control.
2.
Select the frame type(s) to enable storm control.
3.
Set the Rate and Unit parameters.
4.
Click which port you want to enable and configure the Rate limit condition.
5.
Click the Apply button to save the settings.
6.
To cancel the settings, click the Reset button. It will revert to previously saved values.
Figure 6-4: Storm Control Configuration
Parameter descriptions
:
Global Storm Policer Configuration
: Global storm policers for the switch are configured on this page. There is a
unicast storm policer, multicast storm policer, and a broadcast storm policer. These only affect flooded frames,
i.e., frames with a (VLAN ID, DMAC) pair not present in the MAC Address table.
Frame Type
: The frame type (Unicast, Multicast, Broadcast) for which the configuration below applies.
Enable
: Enable or disable the global storm policer for the given frame type.
Rate
: Set the rate for the global storm policer. This value is restricted to 10-13128147 when "Unit" is fps or
kbps, and 1-13128 when "Unit" is kfps or Mbps. The rate is internally rounded up to the nearest value supported
by the global storm policer. Supported rates are divisible by 10 fps or 25 kbps.
Unit
: Select the unit of measure for the global storm policer rate as fps, kfps, kbps or Mbps. The default is ‘fps’.
Buttons
Apply
: Click to save changes.
Reset