Lantronix SM12XPA Скачать руководство пользователя страница 8

Lantronix

 

 

SM12XPA Install Guide 

33847 Rev. B 

                  

https://www.lantronix.com/

  

Software Features 

Layer 2 Switching

 

Management 

Web, SNMP v1/v2/v3c, SSH. CLI, RESTful API 

Spanning Tree 

Supports IEEE 802.1s MSTP, IEEE 802.1w RSTP, and IEEE 802.1d STP 

Spanning Tree 

Protocol (STP)

 

  Standard Spanning Tree 802.1d 

  Rapid Spanning Tree (RSTP) 802.1w 

 

Multiple Spanning Tree (MSTP) 802.1s

 

Port Trunk 

Support IEEE 802.3ad port trunk with link aggregation control protocol (LACP) and 

static trunk 

Trunking

 

Link Aggregation Control Protocol (LACP) IEEE 802.3ad

 

Multicast 

Support IGMP Snooping v1/v2/v3, IGMP Querier, IGMP Proxy, MLD Snooping v1/v2 

VLAN 

Port-based VLAN, IEEE 802.1Q tag based, up to 4k VLAN entries, Q-in-Q. MAC-based 

VLAN, Management VLAN, Private VLAN, Voice VLAN 

VLAN 

Supports up to 4K VLANs simultaneously (out of 4096 VLAN IDs) 

  Port-based VLAN 

  802.1Q tag-based VLAN 

  MAC-based VLAN 

  Management VLAN 

  Private VLAN Edge (PVE) 

  Q-in-Q (double tag) VLAN 

  Voice VLAN 

  GARP VLAN Registration Protocol (GVRP) 

DHCP Relay 

  Relay of DHCP traffic to DHCP server in different VLAN. 

  Works with DHCP Option 82 

IGMP v1/v2/v3 

Snooping 

IGMP limits bandwidth-intensive multicast traffic to only the requesters. Supports 1024 

multicast groups 

IGMP Querier 

IGMP querier is used to support a Layer 2 multicast domain of snooping switches in the 

absence of a multicast router 

IGMP Proxy 

IGMP snooping with proxy reporting or report suppression actively filters IGMP packets 

in order to reduce load on the multicast router 

MLD v1/v2 Snooping  Delivers IPv6 multicast packets only to the required receivers 

Quality of Service 

(QoS) 

Support 8 hardware queues.  

Scheduling: Strict  priority and WRR, Queue assignment based DSCP and class of 

service  

Classification: Port based, 802.1p VLAN priority based, IPv4/IPv6 precedence/ DSCP 

based, DiffServ, Classification and re-marking ACLs 

Rate Limiting: Ingress policer, Egress shaping, rate control and per port 

CFM 

Connectivity Fault Management (CFM) is an IEEE 802.1ag and ITU Y.1731 standard 

for managing connectivity at the Ethernet service level. 

APS 

Ethernet Automatic Protection Switching (APS) is a linear protection scheme designed 

to protect VLAN based Ethernet networks. 

Keychain 

A keychain is a sequence of keys that provides dynamic authentication to ensure 

secure communication by periodically changing the key and authentication algorithm 

without service interruption. When the system time is within the lifetime of a key in a 

keychain, an application uses the key to authenticate incoming and outgoing packets. 

The keys in the keychain take effect one by one according to the sequence of the 

configured lifetimes. In this way, the authentication algorithms and keys are 

dynamically changed to implement dynamic authentication. 

Содержание SM12XPA

Страница 1: ...SM12XPA 12 port Multi Gig SFP with 2 10G 25G SFP28 slots Managed Layer 3 Fiber Switch Install Guide Part Number 33847 Revision B October 2022...

Страница 2: ...current list of our domestic and international sales offices go to www lantronix com about contact Disclaimer All information contained herein is provided AS IS Lantronix undertakes no obligation to u...

Страница 3: ...nsole Port 20 Connecting to a Management Port 20 Installing SFP SFP28 Modules 20 Removing SFP SFP28 Modules 21 Power Supply Information 21 Power Supply Specifications 22 Connecting the AC Power Cord 2...

Страница 4: ...ronix SM12XPA Install Guide 33847 Rev B https www lantronix com 4 Declaration of Conformity 37 RoHS WEEE and Environmental Programs 38 Box Label and Device Label 38 Record Device and System Informatio...

Страница 5: ...all the switch Check switch status by reading the LED behavior Reset the switch or restore it to factory defaults Use a Web browser or the CLI to initially configure the switch Troubleshoot the switch...

Страница 6: ...anning Tree STP Rapid Spanning Tree RSTP and Multiple Spanning Tree MSTP Link Aggregation Control Protocol LACP VLANs supports up to 4K VLANs Port based VLAN 802 1Q tag based VLAN MAC based VLAN Manag...

Страница 7: ...n Precision Time Protocol PTP NTP Loop Protection ITU T G 8031 Ethernet Linear Protection ITU T G 8032 Ethernet Ring Protection Switching Loop Detection and Protection Device Management System DMS Gra...

Страница 8: ...domain of snooping switches in the absence of a multicast router IGMP Proxy IGMP snooping with proxy reporting or report suppression actively filters IGMP packets in order to reduce load on the multic...

Страница 9: ...ach OSPF router maintains an identical database describing the Autonomous System s topology From this database a routing table is calculated by constructing a shortest path tree For more OSPF v2 infor...

Страница 10: ...ort DHCP server to assign IP to DHCP clients Remote Monitoring RMON Embedded RMON agent supports RMON groups 1 2 3 9 history statistics alarms and events for enhanced traffic management monitoring and...

Страница 11: ...tection ITU T G 8031 Supports ITU T G 8031 Ethernet Linear Protection Switching ITU T G 8032 Supports ITU T G 8032 Ethernet Ring Protection Switching Loop Detection Supports Loop Detection and Protect...

Страница 12: ...ecture Port Configuration Total Ports 14 SFP 1G 10G ports 12 SFP28 1G 10G 25G 2 Console 1 RJ45 MAC Addresses 32K MAC address table Backplane 340 Gbps Forwarding 252 876Mpps Jumbo Frames 10K Bytes Dime...

Страница 13: ...owered on correctly Off The switch is not receiving power Red On An abnormal state such as exceeding operating temperature range has been detected in the switch Table 2 Port Status LEDs LED Color Stat...

Страница 14: ...terface SFP and SFP28 Port green LED on SFP Port amber LED on SFP28 Port amber LED on Power module LEDs on Reset Button By pressing the Reset button for a certain period of time you can perform these...

Страница 15: ...w opening The switch ships with one power supply standard order the secondary power supply module for the maximum power Caution Be sure to leave adequate room for the airflow opening Power Supply The...

Страница 16: ...AC power to all power supplies 1Hz Blinking Green AC present Only 12VSB On PS off or PS in Smart On state Amber AC cord unplugged or AC power lost with a second power supply in parallel still with AC...

Страница 17: ...OZ Australia BR Brazil Cautions and Warnings The following conventions are used in this manual to emphasize information important to the reader Danger The described activity or situation might or wil...

Страница 18: ...ester between outdoor device and this switch 2 The marking information is located at the bottom of apparatus IEC 62368 1 3 The equipment is not suitable for use in locations where children are likely...

Страница 19: ...kets to the Switch 2 Place the switch on a rack shelf in the rack Push it in until the oval holes in the brackets align with the mounting holes in the rack posts 3 Attach the brackets to the posts Ins...

Страница 20: ...Optic Association Inc is an international non profit educational association chartered to promote professionalism in fiber optics through education certification and standards Note The SFP SFP28 ports...

Страница 21: ...t the module If the latch is obstructed and you cannot use your finger use a small flat blade screwdriver or other long narrow instrument to open the latch 5 Grasp the SFP SFP28 module and carefully r...

Страница 22: ...rush Current 25 Cold start 55A Leakage Current max 1 6mA Power Factor Correction PFC Test at 115VAC 0 75 20 0 90 50 0 95 100 Protection Over Voltage OVP Y Over Current OCP Y Over Temperature OTP Y No...

Страница 23: ...power supply installed Use the procedure below to install a second power supply Procedure 1 Use a small Phillips head screwdriver to remove the two faceplate mounting screws Keep the screws and facep...

Страница 24: ...om 24 Power Supply Performance The switch has one power supply by default It offers a second supply as an option as shown in the web UI With both power supplies installed they operate in High Availabi...

Страница 25: ...ngs on the left of PC screen Note You can skip steps a c by pressing WinKey R and type ncpa cpl command to get to step 3 directly d Right click on your local adapter and select Properties e In the Loc...

Страница 26: ...ys Wrong username or password After you log on the system monitors the interface for periods of inactivity If the interface is inactive for too long you are automatically logged off The CLI initial us...

Страница 27: ...cal Code NEC or local electrical code approved disconnect device and branch circuit protector must be part of the building s installed wiring to accommodate permanently connected equipment Failure to...

Страница 28: ...ed safety features are not negated during installation of a new network or during modification of an existing network Equipment shall comply with all applicable local and national codes related to saf...

Страница 29: ...orden ge nstalleerd S curit lectrique IMPORTANT Cet quipement doit tre utilis conform ment aux instructions de s curit S hk turvallisuus T RKE T m laite on asennettava turvaohjeiden mukaisesti Sicurez...

Страница 30: ...ave a valid network topology If you no longer experience the problems the new topology is probably at fault Also make sure your network topology contains no data path loops 7 Check the port configurat...

Страница 31: ...fferent AC outlet socket to make sure correct AC source is supplied System LED is Red An abnormal state has been detected by the switch Check the switch system log from the Web UI to understand the ab...

Страница 32: ...evice Status Device Operation Interface AC Voltage V AC Current Consumption A Power Factor Apparent Power VA Real Power W Non loading None 100 0 225 0 942 22 50 21 20 Standby mode 1 minute 10G SFP x 1...

Страница 33: ...ption A Power Factor Apparent Power VA Real Power W Non loading None 240 0 164 0 544 39 36 21 41 Standby mode 1 minute 1G RJ45 x 24 10G SFP x 4 240 0 192 0 636 46 08 29 31 Full loading 60 minutes late...

Страница 34: ...tatus Device Operation Interface AC Voltage V AC Current Consumption A Power Factor Apparent Power VA Real Power W Non loading None 100 0 317 0 886 31 70 28 09 Standby mode 1 minute 10G SFP x 12 25G S...

Страница 35: ...ption A Power Factor Apparent Power VA Real Power W Non loading None 240 0 287 0 405 68 88 27 90 Standby mode 1 minute 1G RJ45 x 24 10G SFP x 4 240 0 306 0 489 73 44 35 91 Full loading 60 minutes late...

Страница 36: ...um riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada European Regulations Warning This is a Class A product In a do...

Страница 37: ...duct Regulations 47 CFRFCC Part 15 Subpart B Class A ANSI C63 4 2014 UKCA and UL Standards EN 62368 1 EN 55032 2015 A11 2020 Class A CISPR 32 2015 Cor 1 2016 Class A AS NZS CISPR 32 2015 Class A EN 61...

Страница 38: ...47 Rev B https www lantronix com 38 RoHS WEEE and Environmental Programs See https www lantronix com legal rohs Box Label and Device Label The labels provide information that can help the Tech Support...

Страница 39: ...resolve the problem e g troubleshooting steps etc ______________ _________________________________________________________________________________________ _____________________________________________...

Страница 40: ...Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Tel 1 800 526 8766 Tel 1 949 453 3990 or https www lantronix com technical support Sales Offices For a...

Отзывы: