13: Maintenance
SLC™ 8000 Advanced Console Manager User Guide
297
2. Enter the following:
Internal Temperature
Site Information
SLC Firmware
Note:
The non-active boot bank is updated during the firmware update, without requiring
a reboot. The configuration on the current boot bank may optionally be copied to the non-
active boot bank during the firmware update.
Reboot
Select this option to reboot the SLC 8000 advanced console manager
immediately. The default is
No
.
Note:
The front panel LCD displays the “Rebooting the SLC” message, and the
normal boot sequence occurs.
Shutdown
Select this option to shut down the SLC unit. The default is
No
.
Current
Displays current temperature.
Low
Sets the acceptable minimum for the internal temperature of the SLC 8000
advanced console manager. If the temperature of the SLC device changes to be
outside of this range, the SLC console manager will issue an SNMP trap.
High
Sets the acceptable maximum for the internal temperature of the SLC unit. If the
temperature of the SLC 8000 advanced console manager changes to be outside
of this range, the SLC unit will issue an SNMP trap.
Calibrate Offset
An offset for calibrating the internal temperature of the SLC console manager. The
offset will be applied one hour after setting the calibration value. Zeroing the
offset will take effect immediately and will cancel any current and/or pending
calibration.
Data Center Rack Row
Set these fields to define the rack row the SLC unit is located within a large data
center. The default for these fields is 1.
Data Center Rack
Cluster
Set these fields to define the rack cluster the SLC 8000 advanced console
manager is located within a large data center. The default for these fields is 1.
Data Center Rack
Set these fields to define the rack the SLC unit is located within a large data
center. The default for these fields is 1.
Site Tag
Tag or description used to identify the location or some other attribute of the SLC.
Current Version
Displays the current firmware version.
Clear FW Update Log
(checkbox)
Clears the contents of the Firmware Update log file.
Firmware Update Log
(link)
To view a log of all prior firmware updates, click the
Firmware Update Log
link.
Update Firmware
To update the SLC firmware, select the checkbox. If you select this option, the
SLC unit reboots after you apply the update. The first time boot for each bank
may take up to 5 minutes. Subsequent boot times will be approximately 2
minutes.
To view a log of all prior firmware updates, click the
Firmware Update Log
link.
Firmware Filename
The name of the firmware update file downloaded from the Lantronix web site.
Содержание SLC 8000 Series
Страница 1: ...Part Number 900 704 R Revision R November 2019 SLC 8000 Advanced Console Manager User Guide ...
Страница 72: ...6 Basic Parameters SLC 8000 Advanced Console Manager User Guide 72 Figure 6 2 Network Network Settings 2 of 2 ...
Страница 88: ...6 Basic Parameters SLC 8000 Advanced Console Manager User Guide 88 Figure 6 7 Network VPN 1 of 2 ...
Страница 149: ...8 USB SD Card Port SLC 8000 Advanced Console Manager User Guide 149 Figure 8 4 Devices USB Modem ...
Страница 174: ...9 Device Ports SLC 8000 Advanced Console Manager User Guide 174 Figure 9 8 Device Ports RPMs Add Device ...
Страница 313: ...13 Maintenance SLC 8000 Advanced Console Manager User Guide 313 Figure 13 12 About SLC ...