Содержание SISPM1040-384-LRT-C

Страница 1: ...SISPM1040 384 LRT C SISPM1040 362 LRT SISPM1040 384 LRT C SISPM1040 362 LRT Managed Hardened PoE Switches Install Guide Part Number 33727 Revision J September 2022...

Страница 2: ...949 453 3990 Fax 949 453 3995 Technical Support Tel 1 800 526 8766 Tel 1 949 453 3990 or https www lantronix com technical support Sales Offices For a current list of our domestic and international s...

Страница 3: ...s add PS DC DUAL 5624T Initial Lantronix rebrand Add IEEE 802 3bt Power Input Ripple and Noise Specification Update contact info Safety Warnings and Cautions These products are not intended for use in...

Страница 4: ...Unpacking 14 Desktop Mounting 14 DIN Rail Mounting 15 Wall Mounting Optional 16 Connecting Copper Ports 17 Installing SFP Modules 17 Connecting the DI DO Relay Wires 18 Digital Input and Digital Outp...

Страница 5: ...Cable Specifications 41 Power Supply Features and Specifications 41 Industrial Power Supply 25105 42 Industrial Power Supply 25104 43 Power Supply Built in DC OK Relay Contact 44 Power Supply Terminal...

Страница 6: ...Hazardous locations Railway Marine Transportation and Substation environments Ordering Information SKU Description SISPM1040 362 LRT Managed Hardened PoE Switch provides 4 10 100 1000Base T PoE ports...

Страница 7: ...d separately OCA P181610 18x16x10 Polycarbonate Enclosure Sold separately Manual Overview This manual describes how to install configure and troubleshoot the PoE Switches including how to Install the...

Страница 8: ...indicate the current status of each port Check these LEDs to determine the port status The following tables detail the functions and descriptions of these LED indicators Table 1 Power LEDs LED Color S...

Страница 9: ...point min Volts V1 PHY TTL LED SFP max 3 465V min 3 135V 5 V2 MAC max 2 625V min 2 375V 5 V3 MAC DDR max 1 575V min 1 425V 5 V4 MAC max 1 05V min 0 95V 5 Issue critical stage for High Temperature ala...

Страница 10: ...to the connected device Amber On An abnormal state such as overload status has been detected in the switch Off The port has no active network cable connected or it is not connected to a PoE PD device...

Страница 11: ...for Single Ring and Ring Failover quick settings as described below See the Web User Guide or the CLI Reference for more information on Ring configuration and setup Table 6 DIP Switch Descriptions RM...

Страница 12: ...e Web User Guide or the CLI Reference for more information Note that Spanning Tree must be disabled for Rapid Ring operation EPS and ERPS are standard protocols that can be used between various vendor...

Страница 13: ...RESET Button Description Task to perform Press RESET for SYS LED Behavior Port Status LED Behavior Reset the Switch 2 7 seconds Blinking Green ALL LEDs are Off Restore to Defaults 7 12 seconds Blinki...

Страница 14: ...g for possible future use One Switch One Terminal Block Euro Block One printed Quick Start Guide One DIN Rail mounting bracket and two screws One DB 9 to RJ 45 Console Cable Power Supply one or two op...

Страница 15: ...s back panel Insert screws and tighten with a screwdriver Figure 2 Attaching DIN Rail Kit to the Switch 2 Insert the upper lip of the DIN rail into the DIN rail mounting kit Press the switch towards t...

Страница 16: ...more details 1 Attach the wall mounting plates to rear panel of the chassis Insert screws and tighten then with a screwdriver to secure the plates Figure 5 Attaching Wall Mounting Plates to the Switc...

Страница 17: ...connect PDs which support power input in 48 56V range to prevent damage to PDs Installing SFP Modules On the SISPM1040 384 LRT C you can install or remove an SFP module from a SFP port without having...

Страница 18: ...res into the and terminals respectively 2 To keep the DI DO Relay wires from pulling loose use a small flat blade screwdriver to tighten the wire clamp screws on the front of the terminal block connec...

Страница 19: ...h or low as DI normal when DI stays in normal assume it s set as low then DO will not response But the voltage input change to high DI will show high abnormal and at the same time DO will automaticall...

Страница 20: ...d Specifications on page 41 Note Both the switch and Power Supply 25105 25104 must have their ground terminals connected to earth ground Caution Tying the output connection of the DC power supply to e...

Страница 21: ...er or place a piece of adhesive tape over the circuit breaker handle to prevent accidental power restoration while you are working on the circuit 3 Insert the negative positive DC wires into the V and...

Страница 22: ...you will use for the initial configuration Make sure the PC has the Ethernet RJ45 connector to be connected to the switch via standard Ethernet LAN cable 2 Reconfigure the PC s IP address and Subnet M...

Страница 23: ...Login page 7 Click Login to log into the switch The startup page displays see the Web User Guide We recommend changing the default credentials before deploying in the network Note The factory default...

Страница 24: ...ss the CLI Attach the RJ 45 serial port on the switch front panel to the cable for Telnet CLI configuration Attach the other end of the DB 9 cable to a PC running Telnet or a terminal emulation progra...

Страница 25: ...uration on page 22 4 If you have physical access to the switch check the port LEDs for switch information See the LED Descriptions on page 8 and Troubleshooting LED Indications on page 26 5 Examine ca...

Страница 26: ...tor plug is firmly inserted and locked into the port at both the switch and the connected device 2 Make sure the connected device is up and running correctly 3 If the symptom still exists try a differ...

Страница 27: ...Global RM Green Amber Ring Master LED LED off disabled no Alarm Green lit Ring Master enabled Amber lit Ring Slave enabled Blinking Amber A single Ring has more than two Masters Global RC Green Amber...

Страница 28: ...This means only single port PSE s should normally be used when PD s are deployed outdoors In summary the PD PSE environment is one of these three combinations 1 PoE Source is indoor PD is indoor Env A...

Страница 29: ...and exact power consumption Calculate PoE Power Budget To calculate how many 802 3at devices the unit supports divide the Total PoE Budget 130 Watts by 30 Watts To calculate the maximum number of 802...

Страница 30: ...e switch port is good Noncompliant cabling or powered devices can cause a PoE port fault use only standard compliant cabling 6 Verify that the total cable length from the switch front panel to the con...

Страница 31: ...o a momentary overcurrent condition The PD starts to power up but then quickly powers down 15 Most PoE switches have voltage and current regulators that detect an overcurrent threshold and disconnect...

Страница 32: ...0 384 LRT C SISPM1040 362 LRT 33729 API User Guide for SISPM1040 384 LRT C and SISPM1040 362 LRT 33824 Release Notes version specific For Lantronix Documentation Firmware App Notes etc go to https www...

Страница 33: ...ribe any action s already taken to resolve the problem e g changing mode rebooting etc ________________ ________________________________________________________________________________________________...

Страница 34: ...Efficient Ethernet standard for green Ethernet application X X IEEE 802 3af at Power over Ethernet X X IEEE 802 3af at Power over Ethernet X X IPv4 IPv6 L3 static route X X ITU T G 8031 Ethernet Line...

Страница 35: ...67F 40 to 75C 40 to 167F 40 to 75C Storage Temperature 40 to 185F 40 to 85C 40 to 185F 40 to 85C Operating Humidity 5 to 95 non condensing 5 to 95 non condensing Altitude 10 000 ft 3000 m 10 000 ft 30...

Страница 36: ...shooting Network diagnostic between master switch and devices Supports protection mechanisms such as rate limiting to protect your devices from brute force downloading Supports performance management...

Страница 37: ...I in the switch IEEE 802 1X IEEE802 1X RADIUS authentication authorization and accounting MD5 hash guest VLAN single multiple host mode and single multiple sessions Supports IGMP RADIUS based 802 1X D...

Страница 38: ...Ports ports can be mirrored to single destination port A single session is supported UPnP The Universal Plug and Play Forum was formed to standardize discovery and control of networked devices See th...

Страница 39: ...f devices connected to the switch interfaces Perform on demand backup and restore of device configuration Perform secure remote device firmware upgrades Lantronix hosted public cloud offering LPM Lant...

Страница 40: ...0W Number of Ports that support PoE 15 4W PoE 30W Each of ports 1 4 support PoE PoE within available PoE SISPM1040 384 LRT C Available PoE Power 240W Number of Ports That Support PoE 15 4W PoE 30W Eac...

Страница 41: ...Watts 25105 Input 85 264 VAC 124 370 VDC Output 48 55 VDC 2 5A 120 Watts PS DC DUAL 5624T Hardened 345 Watt Isolated PS with 56VDC and 24VDC Dual Output Caution Tying the output connection of the DC...

Страница 42: ...0VAC Leakage Current 1 0mA 240VAC Protection Overload 110 150 Overvoltage 56 65V Over Temperature 95 C 5 C Environment Oper Temp 25 C 70 C Stor Temp 40 C 85 C Humidity 20 95 non condensing Features 91...

Страница 43: ...ection Overload 105 160 Overvoltage 56 65V Environment Operating Temp 25 C 70 C Storage Temp 40 C 85 C Operating Humidity 20 95 non condensing Features 94 High Efficiency 150 Peak Load Protected again...

Страница 44: ...n Number Assignments TB1 The power supply s TB1 pinout is provided below Pin Number Assignment 1 FG 2 AC N 3 AC L Power Supply Terminal Block Pin Number Assignments TB2 The power supply s TB2 pinout i...

Страница 45: ...Lantronix Install Guide SISPM1040 362 LRT and SISPM1040 384 LRT C 33727 Rev J https www lantronix com Page 45 of 51 Power Supply Dimensions 25104 SDR 240 48 Dimensions in mm 25104 SDR 240 48...

Страница 46: ...ated PS with 56VDC and 24VDC Dual Output The Power Supply provides 345W at 56VDC and is targeted for PoE applications The Power Supply is fully compliant with IEEE 802 3af at and bt PoE standards for...

Страница 47: ...to comply with the protection requirements of European Emission Standard EN55022 EN61000 3 and the Generic European Immunity Standard EN55024 Declaration of Conformity Manufacture s Name Lantronix In...

Страница 48: ...he possibility of injury to person Cautions and Warnings appear here and may appear throughout this manual where appropriate Failure to read and understand the information identified by this symbol co...

Страница 49: ...anslated into multiple languages Electrical Safety Warnings Electrical Safety IMPORTANT This equipment must be installed in accordance with safety precautions Elektrische Sicherheit WICHTIG F r die In...

Страница 50: ...Canadian National Standards Listed These devices are open type devices that are to be installed in an enclosure only accessible with the use of a tool suitable for the environment This equipment is su...

Страница 51: ...rate Headquarters 48 Discovery Suite 250 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Online https www lantronix com technical support Sales Offices...

Отзывы: