Alarm Relay (Digital Input and Digital Output Relay)
Connecting the DI/DO (Digital Input / Digital Output) Relay
1.
Insert the negative (ground)/positive DI/DO Relay wires into the
+
and
-
terminals,
respectively.
2.
To keep the DI/DO Relay wires from pulling loose, use a small flat-blade screwdriver to
tighten the wire-clamp screws on the front of the Terminal Block connector.
3.
Insert the Terminal Block connector prongs into the Terminal Block receptor.
Note
:
Digital output (relay): 24VDC/1A
Digital input: level 0 (Low) -> 0V to 6V, level 1 (High) -> 10V to 24V
FAULT
: The two contacts of the terminal block connector are used to detect user-configured events.
The two wires attached to the fault contacts form an open circuit when a user-configured event is triggered.
If a user-configured event does not occur, the fault circuit remains closed.