Wired (eth0) Network Failover
The SGX 5150 device gateway provides WAN network failover, in the form of a "dead remote host
reachability" mechanism (essentially a ping against a known host). If the remote host is
determined to be not reachable, the SGX 5150 gateway will failover to the Wi-Fi interface. If the
remote host is determined to be reachable, the gateway will failback to the Ethernet interface.
Table 6-6 Wired (eth0) Network Failover Settings
To View and Configure Wired Network Failover Settings
Using Web Manager
To view Ethernet Failover statistics, click
Network
on the menu and select
Wired Network >
Failover
.
To modify Ethernet Failover settings, click
Network
on the menu and select
Wired Network >
Failover > Configuration
.
Using the CLI
To enter the eth0 link command level:
enable > config > if 1 > failover
Using XML
Include in your file:
<configgroup name="network failover" instance="eth0">
Wireless (wlan0) Network
The wireless network pages are used to configure and view the status of the wireless (wlan0)
interface and link on the SGX 5150 gateway. To see the effect of these items after a reboot, view
the Status page.
Wireless (wlan0) Network Interface
displays the wireless interface status and configuration information. The view-only
status information is available on the Wireless (wlan0) Network Interface Status page. This same
information is configurable on the Wireless (wlan0) Network Interface Configuration page.
Wired Network
(Failover) Settings
Description
State
Click to enable or disable state.
Failover Interface
Always select wlan0 in the SGX 5150 device gateway.
Hostname
Enter the remote host to test reachability.
Method
Select ICMP or TCP based ping.
Timeout
Indicate the interval to wait for ping response from remote host.
Interval
Indicate the interval in which to test reachability
Failover Threshold
Indicate the allowed number of failed pings – after which the SGX 5150 gateway
will failover to the wlan0 interface.
Failback Threshold
Indicate the number of successful pings – after which the SGX 5150 gateway will
failback to the Ethernet interface.