Lantronix
S3100 Install Guide
33581 Rev. C
Page 15 of 19
Troubleshooting
Procedure
1.
Is the
PWR
(power) LED lit?
NO
• Is the S3100 inserted properly into the chassis?
• Is the power cord properly installed in the S3100 and in the grounded AC outlet?
• Does the grounded AC outlet provide power?
• Contact Tech Support.
YES
• Proceed to step 2.
2.
Is the
LINK
LED lit?
NO
• Check that the SFP device is supported and properly connected. See “
on page
• Check the fiber cables for proper connection.
• Re-seat the SFPs. Note that with two copper SFP modules are used in the converter, no link is
established. At least one of the two SFPs must be a fiber SFP.
• Verify that the cable specs are met. See “
Cable Specifications
” on page
27
.
• Contact Tech Support.
Product and Packaging Labels
The product and packaging labels provide valuable information that you can provide to help the Technical
Support Specialist in solving a problem.
Product Label
Packaging Label