A. Mounting 25172
The electrical facility should be setup by qualified specialists in compliance with the applicable electrical
regulations. All regulations and standards which apply locally should be followed. In particular, this includes the
following measures:
• Protection against electrical shock
• Arrangements for a switching or disconnecting mechanism to isolate the power-supply circuit
• Sufficient space for fusing and connection lines
• Allocation of sufficient ventilation (50 mm clearance for air intake from above and below)
• Installation on a mounting rail (in compliance with DIN 50022-35) in housing that is appropriate for the
environmental conditions. Take particular care with the installation position.
B. 25172 Connection
The electrical connection should only be carried out by a qualified technician. These points must be observed:
• The entire electrical facility should be disconnected from the power supply before the installation begins.
• You must ensure that the facility remains voltage-free (i.e., power supply cannot be reconnected).
• All connection lines should be seated and fastened securely. Pay particular attention to the protective-earth
connection.