background image

Lantronix 

 

    ION219-x Install Guide 

33412 Rev. D 

https://www.lantronix.com/

  

11 

IONPS-x Power Supply Specifications 

See the related IONPS-x power supply manual for specifications and standards. 

About this Manual 

This manual provides instructions on how to install and configure the ION219-x Chassis to accommodate various 

types of ION slide-in cards (SICs) and power supplies. 

Related Manuals and Online Help 

A printed documentation card is shipped with each device. Context-sensitive Help screens, as well as  

cursor-over-help (COH) facilities are built into the Web interface.  
For Lantronix Documentation, Firmware, App Notes, etc. go to 

https://www.lantronix.com/technical-support/

.  

Note that this manual provides links to third party web sites for which Lantronix is not responsible.  
For SFP manuals

 

see Lantronix

 

SFP webpage

.

 

Note that this manual provides links to third part web sites for which Lantronix is not responsible. 

Other

 ION System and related device manuals are listed below. 

 

ION Management Module (IONMM) Install Guide, 33420 and User Guide, 33457 

 

ION System x323x Remotely Managed NID User Guide, 33432 

 

ION Systems CLI Reference Manual, 33461 

 

ION x222x & x32xx Multi-port NIDs Installation Guide, 33433 

 

ION219 Cxx1x NID Installation Guides, 33414 - 33417 

 

ION Dry Contact Relay (DCR) Kit Install Guide, 33422 

 

IONPS-A AC Power Supply Install Guide, 33423, 33464 

 

IONPS-D DC Power Supply Install Guide, 33424 

 

IONPS-A-R1 AC Power Supply User Guide, 33614 

 

IONPS-D-R1 DC Power Supply User Guide, 33707 

 

ION ADP Install Guide, 33413 

 

SFP manuals (product specific) 

 

Release Notes (firmware version specific) 

Note

: Information in this document is subject to change without notice. All information was deemed accurate 

and complete at the time of publication. This manual documents the latest software/firmware version. While all 

examples may not display the latest version number, all the descriptions and procedures reflect the latest 

software/firmware version, noted in the 

Record of Revisions

 

 

Содержание ION219-x

Страница 1: ...ION219 x ION 19 Slot Chassis Install Guide Part Number 33412 Revision D January 2022...

Страница 2: ...ales offices go to the Lantronix web site at www lantronix com about contact Disclaimer All information contained herein is provided AS IS Lantronix undertakes no obligation to update the information...

Страница 3: ...nded to be connected to intra building inside plant link segments that are not subject to lightening transients or power faults They are not to be connected to inter building outside plant link segmen...

Страница 4: ...resulting in equipment damage and or possible injury to persons Warning Do not work on the chassis connect or disconnect cables during a storm with lightning Failure to observe this warning could res...

Страница 5: ...Site Requirements 16 AC Power 16 Plant Wiring 16 Site Environment 16 Equipment Racks 16 Installation Procedures 17 Installing the Chassis 17 Tabletop Installation 17 Rack Installation 17 Rack Mount E...

Страница 6: ...stem Information 26 Compliance Information 27 Declaration of Conformity 28 Electrical Safety Warnings 29 Appendix A Cable Specification and Connectors 30 RJ45 Cable 30 Coax Cable and BNC Connectors 31...

Страница 7: ...gure 6 Rack Mount Ear Installation Positions 17 Figure 7 ION219 x Rack Mount Ear Installation 18 Figure 8 Rack Mounting 19 Figure 9 Chassis Grounding Hardware 20 Figure 10 Grounding the Chassis 21 Fig...

Страница 8: ...ION Management Module using a standard web browser such as Internet Explorer or Mozilla Firefox Command Line Interface CLI CLI access can be done via telnet remotely or via the local console port on...

Страница 9: ...ONPS D Redundant 48VDC Power Supply for 19 Slot ION Chassis IONPS A R1 Redundant AC Power Supply for ION219 Chassis IONPS D R1 Redundant 48VDC Power Supply Module for ION19 Chassis WMBC 2RU Wall mount...

Страница 10: ...ply module provides redundancy for instant fail over Power Consumption up to 150 watts Power Source IONPS A IONPS D IONPS A R1 IONPS D R1 Dimensions Width 17 0 430mm x Depth 15 8 401mm x Height 3 5 89...

Страница 11: ...ch Lantronix is not responsible Other ION System and related device manuals are listed below ION Management Module IONMM Install Guide 33420 and User Guide 33457 ION System x323x Remotely Managed NID...

Страница 12: ...ck all ION219 x contents 2 Verify receipt of all ION219 x components Contact your sales representative if any items are missing 3 Place the ION219 x and related materials near the install location 4 S...

Страница 13: ...talled SICs The IONMM controls the specific features and functions of each SIC The ION219 x allows the network administrator to connect various copper and fiber optic network media The ION219 x chassi...

Страница 14: ...Rear The ION219 x is equipped with an AC power supply or an optional DC power supply installed in one of its rear slots An extra installation space is available for an optional AC or DC power supply...

Страница 15: ...nditions that could exist at the installation site so exercise caution at all times Always unplug all power cords before installing or removing the chassis Keep the chassis area clear and dust free du...

Страница 16: ...site When planning the location of the chassis consider the distance limitations of signaling electromagnetic interference EMI and connector capability When wires are run from any significant distance...

Страница 17: ...C 122 F When installing the ION219 x chassis in a closed or multiunit rack assembly the operating ambient temperature of the rack environment could be greater than room ambient Note Reliably groundin...

Страница 18: ...g 1 Determine the preferred alignment of the chassis into the rack 2 Using a Phillips screwdriver remove the six 6 cover to frame screws three on each side of the chassis See Figure 7 below 3 Align th...

Страница 19: ...les in the rack as shown in Figure 8 below 3 Install two 2 screws through the right bracket into the right mounting rail and two 2 screws through the left bracket into the left mounting rail using the...

Страница 20: ...stallations or to an alternate approved grounding system if required for non telecom installations Be sufficiently low in impedance to conduct fault currents likely to be present on the chassis Enable...

Страница 21: ...placing the two hole compression type connector onto the grounding lugs and then fasten with the appropriate lock washers and lug nuts at the proper torque See Figure 10 below 3 Attach the opposite e...

Страница 22: ...switch in the ON position The number designations associated with the LED on the chassis are as follows PS1 refers to the power supply installed in the left primary slot when looking at the chassis f...

Страница 23: ...ower Supply Module Installation Secondary Slot See the related ION Power Supply User Guide e g IONPS A IONPS D IONPS A R1 or IONPS D R1 for specific IONPS x R1 Descriptions Specifications Primary Seco...

Страница 24: ...stalled SICs SIC Monitoring The IONMM and each SIC have one or more LED indicators to help monitor the ION219 x chassis in the network Refer to the user guide for the IONMM and each SIC to interpret t...

Страница 25: ...UTION See the Replace the Fuse section for the proper method to replace the Power Supply fuse Contact Technical Support YES Contact Technical Support 3 When a problem or exception occurs the ION219 x...

Страница 26: ...____________________________________________________________________________ _________________________________________________________________________________________ Describe your network environment...

Страница 27: ...truction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required...

Страница 28: ...nufacture s Name Lantronics Inc Manufacture s Address 48 Discovery Suite 250 Irvine California 92618 USA Declares that the products 19 Slot Rack Mount Chassis ION219 x ION219 A ION219 D ION219 AAMB Co...

Страница 29: ...worden ge nstalleerd S curit lectrique IMPORTANT Cet quipement doit tre utilis conform ment aux instructions de s curit S hk turvallisuus T RKE T m laite on asennettava turvaohjeiden mukaisesti Sicure...

Страница 30: ...network RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD All pin pairs 1 2 3 6 4 5 7 8 are active in a Gigabit Ethernet network See Figure 27 below Use only dedicated wire pairs for the active pins e...

Страница 31: ...DS3 E1 and 10Base 2 Ethernet The impedance of the coaxial cable is determined by the interface type for example 75 ohm for DS3 50 ohm for 10Base 2 Ethernet Coax cable length is dependent upon applicat...

Страница 32: ...e Data 3 D Green Data 4 GND Black Ground Figure 14 USB Peripheral and Cable Ends Cable Shield Grounding Media converter network cabling can be shielded or unshielded Shielded cables must be grounded a...

Страница 33: ...n features Type Attenuation Bandwidth Dispersion Slope Numerical Aperture dB KM 850 1300 1550 MHz KM 850 1300nm ps nm2 km 8 125 0 4 0 25 n a 0 093 0 1 50 125 3 5 1 2 400 600 n a 0 20 62 5 125 3 5 1 2...

Страница 34: ...iscovery Suite 250 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support Online https www lantronix com technical support Sales Offices For a current list of...

Отзывы: