5: Commands and Levels
EDS-MD® Wired IoT Device Gateway Command Reference
430
protocol udp aes
Uses UDP protocol with AES encryption for connect
mode tunneling.
show
Shows the current configuration.
show history
Displays the last 20 commands entered during the
current CLI session.
show statistics
show connection statistics
ssh username
<text>
Sets the SSH user name for use when establishing
tunneling connections with other devices. <text> =
SSH user name.
tcp keep alive idle time
<milliseconds>
Sets the TCP keep alive idle time. This is the initial
keep alive timeout. <milliseconds> = timer value, in
milliseconds.
tcp keep alive interval
<milliseconds>
Enables TCP keep alive for connect mode tunneling
and sets the timer. <milliseconds> = timer value, in
milliseconds.
tcp keep alive probes
<number>
Sets the number of TCP keep alive probes.
<number> = number of TCP keep alive probes.
tcp user timeout
<milliseconds>
Sets the timeout for TCP retransmissions.
<milliseconds> = timeout value, in milliseconds.
validate certificate disable
Skips verification of the server certificate when
connecting.
validate certificate enable
Requires verification of the server certificate when
connecting.
write
Stores the current configuration in permanent
memory.
host 3 (tunnel-connect-host:10:3) level commands
address
<text>
Sets the remote host to establish tunneling
connections with. <text> = IP address or host name
of the remote host.
aes decrypt key
<hexadecimal>
Sets the connect tunnel AES decrypt key with up to
16 bytes. Each byte is represented by two adjacent
hex digits. Bytes may run together or be separated
by optional punctuation: 123ABC "12 3A BC"
12,3A,BC 12.3a.bc 12:3a:bc Note that quotes must
enclose the value if it contains spaces.
aes decrypt key text
<text>
Sets the connect tunnel AES decrypt key with up to
16 bytes. Each byte is represented by a single
character. Note that quotes must enclose the value
if it contains spaces.
aes encrypt key
<hexadecimal>
Sets the connect tunnel AES encrypt key with up to
16 bytes. Each byte is represented by two adjacent
hex digits. Bytes may run together or be separated
by optional punctuation: 123ABC "12 3A BC"
12,3A,BC 12.3a.bc 12:3a:bc Note that quotes must
enclose the value if it contains spaces.
aes encrypt key text
<text>
Sets the connect tunnel AES encrypt key with up to
16 bytes. Each byte is represented by a single
character. Note that quotes must enclose the value
if it contains spaces.
auto show statistics
show connection statistics
clrscrn
Clears the screen.