background image

 

 

 

IPGS-5400-2P 

IGS-5400-2P 

4 Modular Slots Industrial L2+ Managed (PoE) Switch w/ITU 

G.8032 Ring

 

 

User Manual (Hardware) 

 

   

 

 

 

                                                                     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

May.  2016 

Содержание IPGS-5400-2P

Страница 1: ...IPGS 5400 2P IGS 5400 2P 4 Modular Slots Industrial L2 Managed PoE Switch w ITU G 8032 Ring User Manual Hardware May 2016 ...

Страница 2: ...oy an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable It is also mandatory to use an STP cable where the power device like IP camera is used outdoors or wh...

Страница 3: ...n consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does not include or infer any transfer of ownership Interference Issues This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules T...

Страница 4: ...t occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipme...

Страница 5: ...ation 13 Hardware installation 13 3 1 Rack Mounting 14 3 2 Wiring the Power Inputs 16 3 3 Wiring the Fault Alarm Contact 19 3 4 Cabling 20 3 5 USB Dongle 23 Chapter 4 Network Application 24 ITU G 8032 Scheme 24 Ring Coupling 24 Multiple Rings 25 Dual Homing 26 Chain 26 Chapter 5 Console Management 28 5 1 Connecting to the Console Port 28 5 2 Login in the Console Interface 29 ...

Страница 6: ... IEEE 802 1Q VLAN IEEE 802 1p Class of Service IEEE 802 1X Access Control IEEE 802 1D Spanning Tree IEEE 802 1w Rapid Spanning Tree IEEE 802 1s Multiple Spanning Tree IEEE 802 3ad Link Aggregation Control Protocol LACP IEEE 802 1AB Link Layer Discovery Protocol LLDP IEEE 802 1x User Authentication Radius IEEE 1588 Precision Time Protocol v2 IEEE 802 3at af PoE IPGS 5400 2P Switch Architecture Back...

Страница 7: ...ion Yellow MINI GBIC Link Activity Green Power Supply IGS 5400 2P 1 built in power 1 optional power IPGS 5400 2P 1 built in power 1 optional power 1 PoE power VAC VDC isolated 4000V 85V 265VAC 100 370VDC VDC isolated 1600V 36 75VDC 12V 57VDC PoE power input 45 57VDC 55V input is recommended for 802 3at 30W applications IPGS 5400 2P Power Consumption Full load 30W Unload 13W PoE Budget IPGS 5400 2P...

Страница 8: ...g Humidity 5 95 Non condensing Operating Temperature 20 C 60 C Storage Temperature 40 C 85 C EMI FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN 61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN55022 Class A CE EN55024 MTBF 245 432hrs Stability Testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration Warranty 5 years ...

Страница 9: ...r 2 Hardware Description In this paragraph it will describe the Industrial switch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension Metal case IP 30 440 W x 325 D x 44 H mm ...

Страница 10: ...st access to hazardous parts e g electrical conductors moving parts and the ingress of solid foreign objects Level Object size protected against Effective against 0 No protection against contact and ingress of objects 1 50 mm Any large surface of the body such as the back of a hand but no protection against deliberate contact with a body part 2 12 5 mm Fingers or similar objects 3 2 5 mm Tools thi...

Страница 11: ...Test duration 10 minutes Water equivalent to 3 mm rainfall per minute 3 Spraying water Water falling as a spray at any angle up to 60 from the vertical shall have no harmful effect Test duration 5 minutes Water volume 0 7 litres per minute Pressure 80 100 kPa 4 Splashing of water Water splashing against the enclosure from any direction shall have no harmful effect Test duration 5 minutes Water vol...

Страница 12: ...of at least 1 m measured at bottom of device and at least 15 cm measured at top of device 8 Immersion beyond 1 m The equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer Normally this will mean that the equipment is hermetically sealed However with certain types of equipment it can mean that water can enter but only in such a manner ...

Страница 13: ...tive Off Power 1 is inactive PWR2 Green On Power 2 is active Off Power 2 is inactive FAULT Red On Power or port failure Off No failure RJ 45 Link Ack On A network device is detected Blinking The port is transmitting or receiving packets from the TX device Off No device attached Speed 1000M On The port is operating in 1000T mode PoE Off The port is not operating in PoE mode On The port is operating...

Страница 14: ...tion about how to wire the power The power LED on the Industrial switch will light up 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Insert one side of RJ 45 cable category 5 into the Industrial switch Ethernet port RJ 45 port and another side of RJ 45 cable category 5 to the network device s Ethernet port RJ 45 port ex Switch PC or Server The UTP port RJ 45...

Страница 15: ...equipment rack brackets included with the switch Cross head screwdriver not provided Four standard equipment rack screws not provided Perform this procedure to install the switch in a 19 inch equipment rack 1 Secure the two rack mount brackets to the sides of the switch using the eight bracket screws provided 2 Have another person hold the switch in the equipment rack while you secure it using sta...

Страница 16: ...15 ...

Страница 17: ...GS 5400 2P power input 3 is separated with power of switch system power input 1 and 2 The power input module 2 is an optional part There are 4 kinds of power input modules for switch system can be chosen please confirm with the voltage request from field and make sure the chosen module can satisfy voltage of power input ...

Страница 18: ...then insert DC power wires into the contacts V and V of power module 3 For the power module EOTH000704 install the power module then insert DC power wires into the contacts V and V of power module 4 Tighten the wire clamp screws for preventing the wires from loosing 5 For the power module EOTH000703 connect the power cords to the connectors on the back module and to the appropriate power sources ...

Страница 19: ...wires into the contacts and for power 3 for PoE Only for IPGS 5400 2P 7 Tighten the wire clamp screws for preventing the wires from loosing NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG ...

Страница 20: ...he switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG Insert the wires into the fault alarm contacts ...

Страница 21: ...actor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications The SFP slots supporting Gigabit speed up to 1000Mbps They are used for connecting to the network segment with single or multi mode fiber You can choose the appropriate SFP transceiver to plug into the slots Then use proper multi mode or single mode fiber according...

Страница 22: ...21 Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver LC connector to the transceiver ...

Страница 23: ...e follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pull the transceiver out by the plastic handle Pull out from the transceiver ...

Страница 24: ...iguration from web browser or other user interface When you plug USB dongle in switch the switch will backup its configuration file automatically the backup file will be named cfgexport_ switch MAC yml if you want to restore the backup file just rename the configuration file as cfgimport_ switch MAC yml then plug the USB dongle again ...

Страница 25: ...mmunication Unit G 8032 v2 draft The benefits of G 8032 are 1 50ms recovery time when failover 2 G 8032 has defined the protocol scheme parameters functions test measures to be unified that the users can evaluate the possible network infrastructure without literally testing each brand in large scale Ring Coupling ...

Страница 26: ...25 Multiple Rings ...

Страница 27: ...26 Dual Homing Chain ...

Страница 28: ...27 ...

Страница 29: ... cable which one end is DB9 female connector and the other end is DB9 male connector Attach the end of DB9 female connector to PC or terminal and the other end of DB9 male connector to the console port of the switch The connected terminal or PC must support the terminal emulation program ...

Страница 30: ...of the console port Baud Rate 115200 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters Having finished the parameter settings click OK When the blank screen shows up press Enter key to have the login prompt appears Key in admin default value for both User name and Password use Enter key to switch then press Enter and the Main Menu of console manageme...

Страница 31: ...30 Console login interface Notice For web based management please refer to our Software Management Manual at http www lantechcom tw global eng support downloads html ...

Отзывы: