background image

 

 

 

IPGS-3XXX 

IPGS-5XXX 

IGS-3XXX 

IGS-5XXX 

IP30-rated Series 

IP30-rated L2

+

 Industrial Managed Switch w/Enhanced G.8032 Ring

 

 

User Manual (Hardware) 

   

 

                                                                     

 

 

Nov.  2016 

Содержание IPGS-3 Series

Страница 1: ...IPGS 3XXX IPGS 5XXX IGS 3XXX IGS 5XXX IP30 rated Series IP30 rated L2 Industrial Managed Switch w Enhanced G 8032 Ring User Manual Hardware Nov 2016 ...

Страница 2: ...oy an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable It is also mandatory to use an STP cable where the power device like IP camera is used outdoors or wh...

Страница 3: ...n consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does not include or infer any transfer of ownership Interference Issues This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules T...

Страница 4: ...t occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipme...

Страница 5: ...2 DIN Rail Mounting 10 3 3 Wall Mount Plate Mounting 12 3 4 Wiring the Power Inputs 13 3 5 Wiring the Fault Alarm Contact 14 3 6 Cabling 15 3 7 USB Dongle 18 Chapter 4 Network Application 19 ITU G 8032 Scheme 19 Ring Coupling 19 Multiple Rings 20 Dual Homing 21 Chain 21 Chapter 5 Console Management 23 5 1 Connecting to the Console Port 23 5 2 Login in the Console Interface 24 ...

Страница 6: ...IEEE802 3at af Power over Ethernet PoE model Switch Architecture Back plane Switching Fabric Depends on model Packet throughput ability Full Duplex Depends on model Transfer Rate 14 880pps for Ethernet port 148 800pps for Fast Ethernet port 1 488 000pps for Gigabit Ethernet port MAC Address 16K MAC address table Connector 10 100 1000T RJ 45 type connector Mini GBIC 1000 SFP Sockets or 100 1000M SF...

Страница 7: ...tput DO open collector to 40VDC 200mA Power Supply 48 VDC for 802 3af IPGS series 54VDC for 802 3at IPGS series 24 48VDC IGS 5XXX series IGS 3408DSFP 9 5 57VDC IGS 3408GSFP series 9 5 57VDC IPGS series 12V model 90 305VAC 120 430VDC HV model Power Consumption Depends on model PoE Power Budget Depends on model IPGS series Operating Humidity 5 to 95 Non condensing Operating Temperature 40o C 75o C S...

Страница 8: ...8 CE EN61000 4 11 CE EN61000 4 12 CE EN55022 Class A CE EN55024 Stability Testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration For detail specifications please refer to product datasheet The revise authority rights of product specifications belong to Lantech Communications Global Inc Lantech may make changes to specification and product descriptions at anytime without notice ...

Страница 9: ...Commission IEC Solid particle protection The first digit indicates the level of protection that the enclosure provides against access to hazardous parts e g electrical conductors moving parts and the ingress of solid foreign objects Level Object size protected against Effective against 0 No protection against contact and ingress of objects 1 50 mm Any large surface of the body such as the back of ...

Страница 10: ...rainfall per minute 2 Dripping water when tilted up to 15 Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up to 15 from its normal position Test duration 10 minutes Water equivalent to 3 mm rainfall per minute 3 Spraying water Water falling as a spray at any angle up to 60 from the vertical shall have no harmful effect Test duration 5 minutes Water v...

Страница 11: ...ngress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time up to 1 m of submersion Test duration 30 minutes Immersion at depth of at least 1 m measured at bottom of device and at least 15 cm measured at top of device 8 Immersion beyond 1 m The equipment is suitable for continuous immersion in water under condition...

Страница 12: ...s and their meanings for the switch LED Color Status Meaning R M Green On The switch unit is owner switch of ITU Ring Off The switch is not owner switch PWR1 Green On Power 1 is active Off Power 1 is inactive PWR2 Green On Power 2 is active Off Power 2 is inactive FAULT Red On Power or port failure Off No failure RJ45 Port LED Link Ack On A network device is detected Blinking The port is transmitt...

Страница 13: ...8 For PoE model On The port is operating in PoE mode SFP Port LED On A network device is detected Blinking The port is transmitting or receiving packets from the TX device Off No device attached ...

Страница 14: ...how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Insert one side of RJ 45 cable category 5 into the Industrial switch Ethernet port RJ 45 port and another side of RJ 45 cable category 5 to the network device s Ether...

Страница 15: ...il is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch ...

Страница 16: ...e top of DIN Rail into the track Chapter 2 Then lightly push the DIN Rail into the track Chapter 3 Check if the DIN Rail is tightened on the track or not Chapter 4 To remove the industrial switch from the track reverse above steps ...

Страница 17: ...ws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 5 To remove the wall mount plate reverse the above steps NOTE Wall mount kits are optional accessories ...

Страница 18: ...ositive electrode of power contacts 1 and 2 are defined as power input 1 and contacts 5 and 6 are defined as power input 2 you can connect both power input for redundancy but also can connect with single power input to power on switch 2 Tighten the wire clamp screws for preventing the wires from loosing NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG ...

Страница 19: ...he switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG Insert the wires into the fault alarm contacts ...

Страница 20: ...actor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications The SFP slots supporting Gigabit speed up to 1000Mbps They are used for connecting to the network segment with single or multi mode fiber You can choose the appropriate SFP transceiver to plug into the slots Then use proper multi mode or single mode fiber according...

Страница 21: ...16 Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver LC connector to the transceiver ...

Страница 22: ...e follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pull the transceiver out by the plastic handle Pull out from the transceiver ...

Страница 23: ...iguration from web browser or other user interface When you plug USB dongle in switch the switch will backup its configuration file automatically the backup file will be named cfgexport_ switch MAC yml if you want to restore the backup file just rename the configuration file as cfgimport_ switch MAC yml then plug the USB dongle again ...

Страница 24: ...mmunication Unit G 8032 v2 draft The benefits of G 8032 are 1 50ms recovery time when failover 2 G 8032 has defined the protocol scheme parameters functions test measures to be unified that the users can evaluate the possible network infrastructure without literally testing each brand in large scale Ring Coupling ...

Страница 25: ...20 Multiple Rings ...

Страница 26: ...21 Dual Homing Chain ...

Страница 27: ...22 ...

Страница 28: ...tor Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of the switch The connected terminal or PC must support the terminal emulation program DB9 Connector RJ 45 Connector NC 1 Orange White 2 2 Orange 3 3 Green White NC 4 Blue 5 5 Blue White NC 6 Green NC 7 Brown White NC 8 Brown Pin assignment ...

Страница 29: ...of the console port Baud Rate 115200 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters Having finished the parameter settings click OK When the blank screen shows up press Enter key to have the login prompt appears Key in admin default value for both User name and Password use Enter key to switch then press Enter and the Main Menu of console manageme...

Страница 30: ...25 Console login interface Notice For web based management please refer to our Software Management Manual at http www lantechcom tw global eng support downloads html ...