background image

 

13

 

PD devices required. 

 

Pin assignment of Power input (Shipping before Q1 2018) 

 

Pin assignment of Power input (Shipping after Jan 2018) 

 

Pin assignment of Power input (Shipping after May 2018) 

 

  Redundant Power Input 

 

The power input can be supported redundantly. The supply voltage is 

electrically isolated from the housing. 

 
                       

 

3.1.4 Fitting the device, grounding

 

 

Install the system in a dry and clean area to protect the switch to 
get exposed with dirt.     

 

Plug the connector to the power supply plug then turn on the power 

Содержание IPES/IES-0008B Series

Страница 1: ...IPES IES 0008B Series 8 10 100TX w 8 PoE at af Industrial Un Managed Switch User Manual Mar 2019...

Страница 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Страница 3: ...consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does no...

Страница 4: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Страница 5: ...ntent Chapter 1 Introduction 5 Model Lists 5 Chapter 2 Hardware Description 5 2 1 Physical Dimension 5 2 2 Package Content 7 2 3 IP Protection 8 2 4 LED Indicators 11 Chapter 3 Hardware Installation 1...

Страница 6: ...oE ports Power input IPES 0008B 41 54 12V 8 8 Dual 9 56VDC IPES 0008B 41 54 12V 5A 8 8 Dual 9 36VDC IPES 0008B 41 54 72V 8 8 Dual 50 4 90VDC IES 0008B 41 54 12V 8 NA Dual 9 5 60VDC IES 0008B 41 54 72V...

Страница 7: ...6 Aluminum case IP 54...

Страница 8: ...7 2 2 Package Content Manual CD Product By request...

Страница 9: ...t access to hazardous parts e g electrical conductors moving parts and the ingress of solid foreign objects Level Object size protected against Effective against 0 No protection against contact and in...

Страница 10: ...o 15 from its normal position Test duration 10 minutes Water equivalent to 3 mm rainfall per minute 3 Spraying water Water falling as a spray at any angle up to 60 from the vertical shall have no harm...

Страница 11: ...30 minutes Immersion at depth of at least 1 m measured at bottom of device and at least 15 cm measured at top of device 8 Immersion beyond 1 m The equipment is suitable for continuous immersion in wat...

Страница 12: ...tus and their meanings for the switch LED Color Status Meaning PWR1 Green On Power 1 is active Off Power 1 is inactive PWR2 Green On Power 2 is active Off Power 2 is inactive P1 P8 Link Ack On A netwo...

Страница 13: ...Power input PoE budget IPES 0008B 41 54 12V Dual 9 56VDC 60W for 12V input 80W at dual input 120W for 24V 36V input 80W for 72V Input 54V input is recommended for PTZ or heater applications IPES 0008B...

Страница 14: ...er input Shipping after May 2018 Redundant Power Input The power input can be supported redundantly The supply voltage is electrically isolated from the housing 3 1 4 Fitting the device grounding Inst...

Страница 15: ...ground nut M3 Use toothed locking washers for a good electrical connection Ground screw of I P ES 0008B switch 3 1 5 Connect the M12 connector with RJ 45 data cable ports are not used shall be caped...

Страница 16: ...was in working status Note The protection class IP41 54 is only achieved when bolted together The other components attaching to the system have to meet with the IP41 54 protection class in order to r...

Отзывы: