background image

 

 

 

I(P)GS-3208MGSFP 

I(P)GS-3208C 

I(P)GS-3204MGSFP 

I(P)GS-3008 

IP30-rated Series 

IP30-rated L2

+

 Industrial Managed Switch w/Enhanced G.8032 Ring

 

 

User Manual (Hardware) 

   

 

                                                                     

 

 

Mar.  2017 

Содержание IGS-3008

Страница 1: ...I P GS 3208MGSFP I P GS 3208C I P GS 3204MGSFP I P GS 3008 IP30 rated Series IP30 rated L2 Industrial Managed Switch w Enhanced G 8032 Ring User Manual Hardware Mar 2017...

Страница 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Страница 3: ...consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does no...

Страница 4: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Страница 5: ...7 3 2 DIN Rail Mounting 8 3 3 Wall Mount Plate Mounting 10 3 4 Wiring the Power Inputs 11 3 5 Wiring the Fault Alarm Contact 12 3 6 Cabling 13 Chapter 4 Network Application 16 ITU G 8032 Scheme 16 Rin...

Страница 6: ...IGS 3208C 8 2 1 IPGS 3204MGSFP 4 with PoE at af 2 1 IGS 3204MGSFP 4 2 1 IPGS 3008 8 with PoE at af IGS 3008 8 IP30 rated L2 managed Enhanced G 8032 Ring For detail specifications please refer to prod...

Страница 7: ...ommission IEC Solid particle protection The first digit indicates the level of protection that the enclosure provides against access to hazardous parts e g electrical conductors moving parts and the i...

Страница 8: ...ainfall per minute 2 Dripping water when tilted up to 15 Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up to 15 from its normal position Test duration...

Страница 9: ...gress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time up to 1 m of submersion Test duration 30 minutes Immersio...

Страница 10: ...and their meanings for the switch LED Color Status Meaning R M Green On The switch unit is owner switch of ITU Ring Off The switch is not owner switch PWR1 Green On Power 1 is active Off Power 1 is i...

Страница 11: ...6 For PoE model On The port is operating in PoE mode SFP Port LED On A network device is detected Blinking The port is transmitting or receiving packets from the TX device Off No device attached...

Страница 12: ...ow to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Category 5...

Страница 13: ...is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps...

Страница 14: ...ert the top of DIN Rail into the track 2 Then lightly push the DIN Rail into the track 3 Check if the DIN Rail is tightened on the track or not 4 To remove the industrial switch from the track reverse...

Страница 15: ...of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall...

Страница 16: ...sitive electrode of power contacts 1 and 2 are defined as power input 1 and contacts 5 and 6 are defined as power input 2 you can connect both power input for redundancy but also can connect with sing...

Страница 17: ...e switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for w...

Страница 18: ...tor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications The SFP slots supporting Gigabit speed up to 1000Mbps They are used...

Страница 19: ...14 Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver LC connector to the transceiver...

Страница 20: ...follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pull the transceive...

Страница 21: ...munication Unit G 8032 v2 draft The benefits of G 8032 are 1 50ms recovery time when failover 2 G 8032 has defined the protocol scheme parameters functions test measures to be unified that the users c...

Страница 22: ...17 Multiple Rings...

Страница 23: ...18 Dual Homing Chain...

Страница 24: ...19...

Страница 25: ...or Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of the switch The connected terminal or PC must support the terminal emulation program...

Страница 26: ...f the console port Baud Rate 115200 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters Having finished the parameter settings click OK When the blank scr...

Страница 27: ...22 Console login interface Notice For web based management please refer to our Software Management Manual at http www lantechcom tw global eng support downloads html...