Lantech 

IGS-0016 

16 10/100/1000T Industrial Unmanaged 

Ethernet Switch 

IES-0016 

16 10/100TX Industrial Unmanaged 

Ethernet Switch 

 

 

User Manual 

 

     

 

 

 

 

V1.0 

Sep-2019 

 

 

 

Содержание IGS-0016

Страница 1: ...Lantech IGS 0016 16 10 100 1000T Industrial Unmanaged Ethernet Switch IES 0016 16 10 100TX Industrial Unmanaged Ethernet Switch User Manual V1 0 Sep 2019...

Страница 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Страница 3: ...fety Precaution 2 Hardware Description 3 Front Panel 3 Top View 3 Dimensions 4 Wiring the Power Inputs 5 Wiring the Fault Alarm Contact 5 LED Indicators 7 RJ 45 Pin Assignments 8 Cabling 10 Mounting I...

Страница 4: ...Hardware Installation 14 Installation Steps 15 Troubleshooting 16...

Страница 5: ...ffective solution and meets the high reliability requirements demanded by industrial applications Model Lists Model name 10 100 1000T ports 10 100TX ports PoE ports IGS 0016 16 NA IES 0016 16 NA For l...

Страница 6: ...acking List 1 x 16 port Industrial Ethernet Switch 1 x Terminal Block Safety Precaution Attention If DC voltage is supplied by an external circuit please use a protection device on the power supply in...

Страница 7: ...dimensions port cabling information and wiring installation Front Panel The Front Panel of the IGS 0016 IES 0016 are shown as below Front Panel of the Industrial Switch Top View The top panel of the...

Страница 8: ...the Industrial Switch Converter Dimensions The dimensions of IGS 0016 IES 0016 are 49 x 152 x 105 mm W x H x D The figure below gives the dimensions and views of each side of the 16 port Industrial E...

Страница 9: ...al block connector 2 To tighten the wire clamp screws for preventing the DC wires to loose Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the pi...

Страница 10: ...6 Note The wire gauge for the terminal block should be in the range between 12 24 AWG Insert the wires into the fault alarm contact No 3 4...

Страница 11: ...r input 1 is inactive PWR2 Green On Power input 2 is active Off Power input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both functional or no power inputs 1 1...

Страница 12: ...e figures below for straight through and crossover cable schema 10 100Base TX Pinouts Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each wir...

Страница 13: ...below describes the gigabit Ethernet RJ 45 pinouts Pin Signal name Description 1 BI_DA Bi directional pair A 2 BI_DA Bi directional pair A 3 BI_DB Bi directional pair B 4 BI_DC Bi directional pair C 5...

Страница 14: ...a Cabling Use unshielded twisted pair UTP or shielded twisted pair STP cable for RJ 45 connections 100 Category 3 4 or 5 cable for 10Mbps connections 100 Category 5 cable for 100Mbps or 100 Category 5...

Страница 15: ...d on the industrial switch when out of factory If not please refer to the following steps and figure to secure the DIN rail clip on the switch 1 Use the screws to screw on the DIN rail clip on the ind...

Страница 16: ...1 First position the rear side of the switch directly in front of the DIN rail Make sure the top of the clip hooks over the top of the DIN rail 2 Push the unit downward 3 Check the DIN Rail clip is t...

Страница 17: ...from the industrial switch unscrew the screws to remove the DIN Rail clip 2 Place the wall mount plates on the rear panel of the industrial switch 3 Use the screws to secure the wall mount plates on t...

Страница 18: ...14 Hardware Installation In this paragraph we will describe how to install the 8 port 10 100 1000Base TX Industrial Switch and the installation points for the attention...

Страница 19: ...power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twiste...

Страница 20: ...at the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators The Switch can be easily monitored through panel indicators which describes common problems y...