background image

 

 

 

Lantech 

IGS-0008A 

8 10/100/1000T Industrial Switch 

 

 

 

User Manual 

 

 

 

 

                 

 

 

 

V1.00 

Oct-2010

 

Содержание IGS-0008A

Страница 1: ...Lantech IGS 0008A 8 10 100 1000T Industrial Switch User Manual V1 00 Oct 2010...

Страница 2: ...3 Safety Precaution 3 Hardware Description 4 Dimensions 4 Wiring the Power Inputs 5 LED Indicators 6 RJ 45 Pin Assignments 7 Cabling 9 Mounting Installation 10 DIN Rail Mounting 10 Wall Mount Plate M...

Страница 3: ...witch provides 9 56 VDC dual power inputs When power failure occurs the device will automatically switch to the secondary power input Flexible Mounting The industrial switch is extremely compact and c...

Страница 4: ...eed BW Synchronous timing Provides 192Kbits memory buffer 4K entry MAC address table 9720 bytes jumbo frame Supports full half duplex flow control Supports broadcast storm protection Supports MDI MDI...

Страница 5: ...00 1000Base T Industrial Ethernet Switch 1 x User Manual 2 x Wall Mounting Brackets with screws Safety Precaution Attention If DC voltage is supplied by an external circuit please use a protection dev...

Страница 6: ...sions port cabling information and wiring installation Dimensions The dimensions of the standard model that is not equipped with side heatsinks are 36 2 x 142 x 105 mm W x H x D The figure below gives...

Страница 7: ...ower wires Note The wire gauge for the terminal block should be in the range between 12 24 AWG V V V V1 1 Insert the positive and negative wires into the V and V contacts on the terminal block connect...

Страница 8: ...active Off Power input 1 is inactive P2 Green On Power input 2 is active Off Power input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Power input 1 and 2 are both functional or no po...

Страница 9: ...e figures below for straight through and crossover cable schema 10 100Base TX Pinouts Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each wir...

Страница 10: ...below describes the gigabit Ethernet RJ 45 pinouts Pin Signal name Description 1 BI_DA Bi directional pair A 2 BI_DA Bi directional pair A 3 BI_DB Bi directional pair B 4 BI_DC Bi directional pair C 5...

Страница 11: ...a Cabling Use unshielded twisted pair UTP or shielded twisted pair STP cable for RJ 45 connections 100 Category 3 4 or 5 cable for 10Mbps connections 100 Category 5 cable for 100Mbps or 100 Category 5...

Страница 12: ...d on the industrial switch when out of factory If not please refer to the following steps and figure to secure the DIN rail clip on the switch 1 Use the screws to screw on the DIN rail clip on the ind...

Страница 13: ...1 First position the rear side of the switch directly in front of the DIN rail Make sure the top of the clip hooks over the top of the DIN rail 2 Push the unit downward 3 Check the DIN Rail clip is t...

Страница 14: ...ial switch unscrew the screws to remove the DIN Rail clip 2 Place the wall mount plates on the rear panel of the industrial switch 3 Use the screws to secure the wall mount plates on the industrial sw...

Страница 15: ...13 Hardware Installation In this paragraph we will describe how to install the 8 port 10 100 1000Base TX Industrial Switch and the installation points for the attention...

Страница 16: ...power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twiste...

Страница 17: ...at the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators The Switch can be easily monitored through panel indicators which describes common problems y...

Страница 18: ...16...

Отзывы: