Ground screw 

 

          3.1.5 Connect the M12 connector with RJ-45 data cable, ports are not 

used shall be caped that comes with the package to insulate the 
surrounding.   

 
 

Содержание IES-5416DF Series

Страница 1: ...IPES IES 5416DF IPES IES 5216DF Series 16 10 100TX 4 or 2 100 1000FX Dual Speed Fiber L2 w PoE at af EN50155 Managed Ethernet Switch User Manual Hardware IP 67 IP 54 Apr 2019...

Страница 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Страница 3: ...consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does no...

Страница 4: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Страница 5: ...ion 12 2 3 LED Indicators 15 Chapter 3 Hardware Installation 17 Chapter 4 Network Application 22 4 1 ITU G 8032 Scheme 22 4 2 Ring Coupling 22 4 3 Multiple Rings 23 4 4 Dual Homing 24 4 5 Chain 24 Cha...

Страница 6: ...8 or 16 PoE at af IPES 5216DF series 16 10 100TX PoE at af 2 Dual Speed Fiber L2 EN50155 Managed IP67 IP54 Ethernet Switch w 8 or 16 PoE at af IES 5416DF series 16 10 100TX PoE at af 4 Dual Speed Fibe...

Страница 7: ...paragraph it will describe the Industrial switch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension IPES 5416DF Aluminum case IP 67 285 W x 193 D x 91 2 H mm Alumi...

Страница 8: ...7 IES 5416DF Aluminum case IP 67 285 W x 193 D x 91 2 H mm...

Страница 9: ...8 Aluminum case IP 54 252 W x 179 5 D x 91 H mm...

Страница 10: ...9 IPES 5216DF Aluminum case IP 67 285 W x 201 4 D x 84 4 H mm Aluminum case IP 54 285 W x 201 4 D x 84 4 H mm...

Страница 11: ...10 IES 5216DF Aluminum case IP 67 285 W x 201 4 D x 84 4 H mm...

Страница 12: ...11 Aluminum case IP 54 285 W x 201 4 D x 84 4 H mm...

Страница 13: ...al Protection Rating classifies and rates the degree of protection provided against the intrusion including body parts such as hands and fingers dust accidental contact and water in mechanical casings...

Страница 14: ...iberate contact with a body part 2 12 5 mm Fingers or similar objects 3 2 5 mm Tools thick wires etc 4 1 mm Most wires screws etc 5 Dust protected Ingress of dust is not entirely prevented but it must...

Страница 15: ...inst the enclosure from any direction shall have no harmful effect Test duration 5 minutes Water volume 10 litres per minute Pressure 80 100 kPa 5 Water jets Water projected by a nozzle 6 3 mm against...

Страница 16: ...er but only in such a manner that it produces no harmful effects Test duration continuous immersion in water Depth specified by manufacturer 9 Powerful high temperature water jets Protected against cl...

Страница 17: ...16 Lnk Act On A network device is detected Blinking The port is transmitting or receiving packets from the TX device Off No device attached PoE 1 8 On The port is operating in PoE mode IPES Off The po...

Страница 18: ...2 connector 12V model The power input voltage can be from 9V to 60VDC 72V model The power input voltage can be from 50 4V to 90VDC 110V model The power input voltage can be from 43V to 137 5VDC WV mod...

Страница 19: ...exceed 48VDC for 802 3af and 53VDC for 802 3at operation with IPES 5416DF 72V only 72VDC can power both the 802 3af and 802 3at PD with IPES 5416DF 110V only 110VDC can power both the 802 3af and 802...

Страница 20: ...the two supply voltages The break link status of at least one switch port 3 1 4 Fitting the device grounding Install the system in a dry and clean area to protect the switch to get exposed with dirt P...

Страница 21: ...20 Ground screw 3 1 5 Connect the M12 connector with RJ 45 data cable ports are not used shall be caped that comes with the package to insulate the surrounding...

Страница 22: ...s in working status Note The protection class IP67 IP54 is only achieved when bolted together The other components attaching to the system have to meet with the IP67 IP54 protection class in order to...

Страница 23: ...munication Unit G 8032 v2 draft The benefits of G 8032 are 1 50ms recovery time when failover 2 G 8032 has defined the protocol scheme parameters functions test measures to be unified that the users c...

Страница 24: ...23 4 3 Multiple Rings...

Страница 25: ...24 4 4 Dual Homing 4 5 Chain...

Страница 26: ...25...

Страница 27: ...r to the console port of the switch The connected terminal or PC must support the terminal emulation program 5 2 Login in the Console Interface When the connection between Switch and PC is ready turn...

Страница 28: ...t appears Key in admin default value for both User name and Password use Enter key to switch then press Enter and the Main Menu of console management appears Please see below figure for login screen C...

Отзывы: