background image

 

Chapter 2  Hardware Description 

 

 

In  this  paragraph,  it  will  describe  the  Industrial  switch

’s  hardware  spec,  port,  cabling 

information, and wiring installation. 

 

2.1  Physical Dimension 

 

72mm x 105mm x 152mm

(W x D x H) 

 

2.2  Front Panel 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Front Panel of the industrial switch 

 

Содержание IES-2208CA

Страница 1: ...Lantech IES 2208CA 8 10 100TX 2 10 100 1000T Dual Speed SFP Combo Managed Industrial Switch User Manual V2 01 Jan 2013 ...

Страница 2: ...Hardware Installation 12 3 1 Installation Steps 12 3 2 DIN Rail Mounting 13 3 3 Wall Mount Plate Mounting 15 3 4 Wiring the Power Inputs 16 3 5 Wiring the Fault Alarm Contact 17 3 6 Cabling 18 Chapter 4 Network Application 22 4 1 Pro Ring2s Application 23 Chapter 5 Console Management 24 5 1 Connecting to the Console Port 24 5 2 Pin Assignment 24 5 3 Login in the Console Interface 25 5 4 CLI Manage...

Страница 3: ... 39 SNMP Agent 39 6 20 1 SNMP Trap Configuration 41 6 10 System Alert Relay Alarm 42 6 8 1 System Alert SMTP 42 6 8 2 System Alert Event 44 6 11 DHCP Server 46 6 6 1 DHCP Server Server configuration 46 6 6 2 Client Table 47 6 6 3 IP Bindings 47 6 12 Port Configuration 49 6 13 Port Status 50 6 14 Port Statistics 51 6 15 Port Port Alert 53 6 16 Rate Control Rate Limit 54 6 17 Aggregation Configurati...

Страница 4: ...nfiguration 72 6 24 2 Switch Status 75 6 25 QoS 76 6 25 1 Global Settings 76 6 25 2 Port Priority 77 6 25 3 COS Mapping to Queue 78 6 25 4 DSCP mapping to queue 79 6 25 Port Mirroring 81 6 26 Security 82 6 26 1 IP Source Guard Configuration 82 6 26 2 IP Source Guard Static Table 83 6 26 3 802 1X Radius 84 6 26 4 MAC Filtering 87 6 26 5 Port Security 88 You can block the un authorized MAC by oer po...

Страница 5: ...3 Backup Restore Commands Set 104 Upgrade Firmware Commands Set 104 DHCP Server Commands Set 104 Port Control Commands Set 106 Port Status Commands Set 108 Rate Limit Commands Set 108 Trunk Commands Set 109 PRO RING IIS Commands Set 111 RSTP Commands Set 111 VLAN Commands Set 113 SNMP Commands Set 116 Traffic Prioritization Commands Set 117 IGMP Commands Set 118 Multicast Static Filtering Table Co...

Страница 6: ... Port Statistics Commands Set 128 Port Monitoring Commands Set 128 System Event Log Commands Set 129 Ping Commands Set 129 SFP Monitor Commands Set 129 Loading Average Commands Set 129 Save Configuration Commands Set 132 Factory Default Commands Set 132 System Reboot Commands Set 132 Logout Commands Set 132 FCC Warning ...

Страница 7: ...r in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment int...

Страница 8: ...ase TX FX IEEE802 3ab 1000Base T IEEE802 3z Gigabit fiber IEEE802 3x Flow Control and Back Pressure IEEE802 3ad Port trunk with LACP IEEE802 1d Spanning Tree IEEE802 1w Rapid Spanning Tree IEEE802 1p Class of Service IEEE802 1Q VLAN Tag IEEE 802 1x User Authentication Radius IEEE802 1ab LLDP Switch Architecture Back plane Switching Fabric 7 4Gbps Packet throughput ability Full Duplex 8 3Mpps 64byt...

Страница 9: ...00m Optical Fiber Distance Multi mode 0 to 5 km 1300 nm 50 125 μm 800 MHz km 0 to 4 km 1300 nm 62 5 125 μm 500 MHz km Single mode 0 to 40 km 1310 nm 9 125 μm 3 5 PS nm km 0 to 80 km 1550 nm 9 125 μm 19 PS nm km Min TX Output Multi mode 20 dBm Single mode 0 to 40 km 5 dBm 0 to 80 km 5 dBm Max TX Output Multi mode 14 dBm Single mode 0 to 40 km 0 dBm 0 to 80 km 0 dBm Sensitivity 36 to 32 dBm Single m...

Страница 10: ...to 95 Non condensing Operating Temperature 40o C 75o C Storage Temperature 40o C 85o C Case Dimension IP 30 72mm W x 105mm D x 152mm H Installation DIN rail and wall mount ear EMI FCC Class A CE EN61000 4 2 CE EN61000 4 3 CE EN 61000 4 4 CE EN61000 4 5 CE EN61000 4 6 CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 Safety UL cUL CE EN60950 1 Stability Testing IEC60068 2...

Страница 11: ...Supports LLDP allowing switch to advertise its identification and capability on the LAN Spanning tree IEEE802 1d spanning tree IEEE802 1w rapid spanning tree Pro Ring2s Supports Pro Ring2s Provides redundant backup feature and the recovery time below 20ms Quality of Service The quality of service determined by port Tag and IPv4 Type of service IPv4 Different Service Class of Service Supports IEEE8...

Страница 12: ...type combination rules are Broadcast Multicast Unknown Unicast packet Broadcast Multicast packet Broadcast packet only and all of packet The packet filter rate can be set from 100K 102400Kbps 10 100 100K 256000Kbps 1000 Flow Control Supports Flow Control for Full duplex and Back Pressure for Half duplex System Log Supports System log record and remote system log server SMTP Supports SMTP Server an...

Страница 13: ...ynchronize system clock in Internet Firmware Update Supports TFTP firmware update TFTP backup and restore Configuration Upload Download Supports binary format configuration file for system quick installation ifAlias Each port allows importing 128bits of alphabetic string of word on SNMP and CLI interface ...

Страница 14: ... 2 10 100 1000T Dual Speed SFP Combo Managed Industrial Switch x 1 User manual x 1 Pluggable Terminal Block x 1 Mounting plate x 2 RJ 45 to DB9 Female cable x 1 Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service ...

Страница 15: ...on In this paragraph it will describe the Industrial switch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension 72mm x 105mm x 152mm W x D x H 2 2 Front Panel Front Panel of the industrial switch ...

Страница 16: ...9 2 3 Bottom View The bottom panel of the Industrial Managed Industrial Switch has one terminal block connector of two DC power inputs and one fault alarm Bottom Panel of the industrial switch ...

Страница 17: ...s power on Off No power R M Green On The industrial switch is the master of Pro Ring2s group Off The industrial switch is not a ring master in Pro Ring2s group PWR1 Green On Power 1 is active Off Power 1 is inactive PWR2 Green On Power 2 is active Off Power 2 is inactive FAULT Red On Power or port failure Off No failure P9 P10 RJ 45 Green Upper LED On A network device is detected Blinking The port...

Страница 18: ...ted Blinking The port is transmitting or receiving packets from the TX device Off No device attached Amber On The port is operating in full duplex mode Blinking Collision of Packets occurs Off The port is in half duplex mode or no device is attached FWD P1 P8 Green Green A powered device is connected utilizing Power over Ethernet on the port Off No device is connected or power forwarding fails ...

Страница 19: ... section for knowing the information about how to wire the power The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Insert one side of RJ 45 cable category 5 into the Industrial switch Ethernet port RJ 45 port and another side of RJ 45 cab...

Страница 20: ...il is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following pictures to screw the DIN Rail on the switch Follow the steps below to hang the industrial switch ...

Страница 21: ...nsert the top of DIN Rail into the track 2 Then lightly push the DIN Rail into the track 3 Check if the DIN Rail is tightened on the track or not 4 To remove the industrial switch from the track reverse above steps ...

Страница 22: ...l switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 5 To remove the wall mount plate reverse the above steps ...

Страница 23: ... insert the power wire 1 Insert AC or DC power wires into the contacts 1 and 2 for power 1 or 5 and 6 for power 2 Tighten the wire clamp screws for preventing the wires from loosing NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG ...

Страница 24: ...he switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for wiring the fault alarm contacts NOTE The wire gauge for the terminal block should be in the range between 12 24 AWG Insert the wires into the fault alarm contacts ...

Страница 25: ...l transceiver used in optical communications for both telecommunication and data communications The SFP slots supporting dual mode can switch the connection speed between 100 and 1000Mbps They are used for connecting to the network segment with single or multi mode fiber You can choose the appropriate SFP transceiver to plug into the slots Then use proper multi mode or single mode fiber according ...

Страница 26: ...ollow the steps shown below First insert the transceiver into the SFP module Notice that the triangle mark is the bottom of the module Transceiver to the SFP module Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver ...

Страница 27: ...20 LC connector to the transceiver ...

Страница 28: ...e follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pull the transceiver out by the plastic handle Pull out from the transceiver ...

Страница 29: ...er 4 Network Application This chapter provides some sample applications to help user to have more actual idea of industrial switch function application A sample application of the industrial switch is as below ...

Страница 30: ...to pre set the Master switch in old Pro Ring and yet to protect the network by much secure topologies than ever Pro Ring II works as a Ring Chain to reduce the risk of master switch linking down whereas the setup becomes much easier Pro Ring II can be backward compatible with old Pro Ring by down grading the Ring scheme to old one ...

Страница 31: ...r Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of the switch The connected terminal or PC must support the terminal emulation program 5 2 Pin Assignment DB9 Connector RJ 45 Connector NC 1 Orange White 2 2 Orange 3 3 Green White NC 4 Blue 5 5 Blue White NC 6 Green NC 7 Brown White NC 8 Brown ...

Страница 32: ...ole port Baud Rate 9600 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters Having finished the parameter settings click OK When the blank screen shows up press Enter key to have the login prompt appears Key in root default value for both User name and Password use Enter key to switch then press Enter and the Main Menu of console management appears Ple...

Страница 33: ...I Management The system supports the console management CLI command After you log in on to the system you will see a command prompt To enter CLI management interface type in enable command CLI command interface ...

Страница 34: ...Management supports Internet Explorer 6 0 or later version And it is applied for Java Applets for reducing network bandwidth consumption enhance access speed and present an easy viewing screen 6 2 Preparing for Web Management Before using the web management install the industrial switch on the network and make sure that any one of the PCs on the network can connect with the industrial switch throu...

Страница 35: ...dress of the switch and then Press Enter 3 The login screen will appear right after 4 Key in the user name and password The default user name and password are the same as root 5 Press Enter or click the OK button and then the home screen of the Web based management appears Login screen ...

Страница 36: ...scription Describes the switch System Location Assign the switch physical location The maximum length is 64 bytes System Contact Enter the name of contact person or organization System OID SNMP OID of switch Firmware Version Displays the switch s firmware version Kernel Version Displays the kernel software version MAC Address Displays the unique hardware address assigned by manufacturer 6 4 2 Gene...

Страница 37: ...d Average Sometimes the user was worry about that Could my switch process too many network packets So the network throughput was keeping decreasing In this option you can monitor the CPU of switch to see if the switch was in full loading status or not ...

Страница 38: ...31 ...

Страница 39: ...ight saving time DST is the convention of advancing clocks so that afternoons have more daylight and mornings have less Typically clocks are adjusted forward one hour near the start of spring and are adjusted backward in autumn SNTP Client Enable disable SNTP function to get the time from the SNTP server UTC Timezone Universal Time Coordinated Set the switch location time zone The following table ...

Страница 40: ...Middle European MEWT Middle European Winter SWT Swedish Winter 1 hour 1 pm EET Eastern European USSR Zone 1 2 hours 2 pm BT Baghdad USSR Zone 2 3 hours 3 pm ZP4 USSR Zone 3 4 hours 4 pm ZP5 USSR Zone 4 5 hours 5 pm ZP6 USSR Zone 5 6 hours 6 pm WAST West Australian Standard 7 hours 7 pm CCT China Coast USSR Zone 7 8 hours 8 pm JST Japan Standard USSR Zone 8 9 hours 9 pm EAST East Australian Standar...

Страница 41: ...eriod and Daylight Saving Offset again Daylight Saving Period Set up the Daylight Saving beginning date time and Daylight Saving ending date time Please key in the value in the format of YYYYMMDD and HH MM leave a space between YYYYMMDD and HH MM YYYYMMDD an eight digit year month day specification HH MM a five digit including a colon mark hour minute specification For example key in 20070701 02 0...

Страница 42: ...e web management login user name and password for the management security issue User name Type in the new user name The default is root New Password Type in the new password The default is root Confirm password Re type the new password And then click Apply ...

Страница 43: ...user should find the new IP on the DHCP server IP Address Assign the IP address that the network is using If DHCP client function is enabled this switch is configured as a DHCP client The network DHCP server will assign the IP address to the switch and display it in this column The default IP is 192 168 16 1 or the user has to assign an IP address manually when DHCP Client is disabled Subnet Mask ...

Страница 44: ...37 IP Addressing interface ...

Страница 45: ...guration Syslog Configuration interface Syslog Mode Select the system log mode Client Only Server Only or Both Client Only means the system event log will only be sent to this interface of the switch but on the other hand Server Only means the system log will only be sent to the remote system log server with its IP assigned If the mode is set in Both the system event log will be sent to the remote...

Страница 46: ...es from network devices implementing SNMP SNMP Agent Agent Mode Select the SNMP version V1 V2c or V3 that you want to use it And then click Change to switch to the selected SNMP version mode SNMP V1V2c Community Here you can define the new community string set and remove the unwanted community string Community String Fill the name string Privilege Read only Enables requests accompanied by this com...

Страница 47: ...40 SNMP Agent Configuration interface ...

Страница 48: ...s a trap manager assign an IP address enter the SNMP community strings and select the SNMP trap version Server IP Enter the IP address of the trap manager Community Enter the community string for the trap station Trap Version Select the SNMP trap version type v1 or v2c Click Add To remove the community string select the community string listed in the current managers field and click Remove Trap Ma...

Страница 49: ... be ticked first Please refer to the segment of Wiring the Fault Alarm Contact for the failure detection Power Failure Setting Tick the check box to enable the function of lighting up the FAULT LED on the panel when power fails Port Link Down Broken Setting Tick the check box to enable the function of lighting up FAULT LED on the panel when Ports states are link down or broken Fault Relay Alarm in...

Страница 50: ...vailable Sender Email Address Type in an alias of the switch in complete email address format e g switch101 123 com to identify where the e mail alert comes from Mail Subject Input the subject of Email Authentication Having ticked this checkbox the mail account password and confirm password column fields will then show up Configure the email account and password for authentication when this switch...

Страница 51: ... 3 event types Device Cold Start Authentication Failure and X ring Topology Change The checkboxes are not available for ticking unless the Syslog Client Mode on the Syslog Configuration tab and the E mail Alert on the SMTP Configuration tab are enabled first System Restart When the device executes cold start action the system will issue the event log email alert to the system log SMTP server respe...

Страница 52: ...45 respectively SNMP Authentication Failure When the SNMP authentication fails the system will issue the event log email alert to the system log SMTP server respectively Event Configuration interface ...

Страница 53: ... DHCP server 6 6 1 DHCP Server Server configuration DHCP Server Enable or Disable the DHCP Server function Enable the switch will be the DHCP server on your local network Start IP Address Type in an IP address Low IP address is the beginning of the dynamic IP range For example dynamic IP is in the range between 192 168 16 100 192 168 16 200 In contrast 192 168 16 100 is the Low IP address End IP A...

Страница 54: ...ess of the client device the IP assigning type status and lease time 6 6 3 IP Bindings Assign the dynamic IP address bound with the port to the connected client The user is allowed to fill each port column with one particular IP address When the device is connecting to the port and asks for IP assigning the system will assign the IP address bound with the port ...

Страница 55: ...48 ...

Страница 56: ...s auto or set speed and negotiated way manually Flow Control Whether or not the receiving node sends feedback to the sending node is determined by this item When enabled once the device exceeds the input data rate of another device the receiving device will send a PAUSE frame which halts the transmission of the sender for a specified period of time When disabled the receiving device will drop the ...

Страница 57: ...50 Port Control interface 6 13 Port Status It will show you the status of port configuration setting ...

Страница 58: ...x Good Packet The counts of transmitting good packets via this port Tx Bad Packet The counts of transmitting bad packets including undersize less than 64 octets oversize CRC Align errors fragments and jabbers packets via this port Rx Good Packet The counts of receiving good packets via this port Rx Bad Packet The counts of receiving good packets including undersize less than 64 octets oversize CRC...

Страница 59: ...52 Port Statistics interfac ...

Страница 60: ...entication Failure When the SNMP authentication fails the system will issue the event log email alert to the system log SMTP server respectively MAC Violation When the MAC address has violated the system will issue the event log email alert to the system log SMTP server respectively Port event selection Also before the drop down menu items are available the Syslog Client Mode selection item on the...

Страница 61: ...ation type All the ports support port egress rate control For example assume port 1 is 10Mbps users can set it s effective egress rate is 1Mbps ingress rate is 500Kbps The switch performs the ingress rate by packet counter to meet the specified rate And then click Apply to apply the settings ...

Страница 62: ...pes for selecting All Broadcast Multicast Flooded Unicast Broadcast Multicast Broadcast only Broadcast Multicast Flooded Unicast Broadcast Multicast and Bbroadcast only types are only for ingress frames The egress rate only supports All type And then click Apply to apply the settings ...

Страница 63: ...etwork cable Link Aggregation Control Protocol LACP which is a protocol running on layer 2 provides a standardized means in accordance with IEEE 802 3ad to bundle several physical ports together to form a single logical channel All the ports within the logical channel or so called logical aggregator work at the same connection speed and LACP operation requires full duplex mode ...

Страница 64: ...ge of having the LACP disabled is that a port joins the trunk group without any handshaking with its member ports but member ports won t know that they should be aggregated together to form a logic trunk group Work ports This column field allows the user to choose the total number of active port up to four With LACP static trunk group e g you assign four ports to be the members of a trunk group wh...

Страница 65: ...58 Port Trunk Aggregator Setting interface four ports are added to the left field with LACP enabled ...

Страница 66: ...59 6 17 2Aggregator Status You can check the setting of Port aggregation in Status ...

Страница 67: ...h The value must be a multiple of 4096 according to the protocol standard rule Max Age The number of seconds a switch waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 Hello Time The time that controls the switch to send out the BPDU packet to check RSTP current status Enter a value between 1 through 10 Forw...

Страница 68: ...lows the P2P status of the link to be manipulated administratively True means the port is regarded as a point to point link False means the port is regarded as a shared link Auto means the link type is determined by the auto negotiation between the two peers Edge The port directly connected to end stations won t create bridging loop in the network To configure the port as an edge port set the port...

Страница 69: ...62 6 18 2 RSTP Information This web page provides the port and switch information about RSTP RSTP System Configuration interface ...

Страница 70: ...ust set your switch as Enable or Backup Enable means this switch will play the role of root switch Backup means this switch will take over the role of root switch when the original root switch fail Port setting set the port which you want to build the Ring topology usually set as G1 and G2 With some advance redundancy solution like Couple ring and Dual homing if you are confused about which port w...

Страница 71: ...64 RSTP Port Configuration interface ...

Страница 72: ...er to indicate that the host wants to be or is a member of a given group indicated in the report message Leave Group A message sent by a host to the querier to indicate that the host has quit being a member of a specific multicast group 6 20 1 IGMP Snooping The switch support IP multicast you can enable IGMP protocol on web management s switch setting advanced page then the IGMP snooping informati...

Страница 73: ...n the specific multicast groups With multicast filtering network devices only forward multicast traffic to the ports that are connected to the registered end stations IP Address Assign a multicast group IP address in the range of 224 0 0 0 239 255 255 255 Member Ports Tick the check box beside the port number to include them as the member ports in the specific multicast group IP address Click Add ...

Страница 74: ...67 field and click Delete to remove it ...

Страница 75: ...mation about themselves to other nodes on the network and store the information they discover LLDP runs on all 802 media The protocol runs over the data link layer only allowing two systems running different network layer protocols to learn about each other 6 21 1 LLDP Configuration LLDP Protocol Pull down the selection menu to disable or enable LLDP function LLDP Interval Set the interval of adve...

Страница 76: ...69 6 22 1 LLDP Neighbors It will show you the information about Port Neighbor via LLDP protocol ...

Страница 77: ...rt security 6 23 1 Configuration MAC Address Configuration Set the Aging time of MAC address table and define the event about port fail will influent the MAC table automatically or not Port Setting Define which port will be managed by Static MAC address table Click Apply ...

Страница 78: ...71 6 23 1 Dynamic MAC table You can monitor the learning status of MAC address table in this function ...

Страница 79: ... a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physically This switch supports Port based and 802 1Q tagged based VLAN The default configuration of VLAN operation mode is Disable 6 24 1 VLAN Configuration Operation Mode Enter the MAC address of the port that should permane...

Страница 80: ...yte tag in the frame The contents of the last 12 bit of the tag is untagged VID When this frame is sent out through any of the access port of the same PVID the switch will remove the tag from the frame to recover it to what it was Those ports of the same untagged VID are regarded as the same VLAN group members Note Because the access port doesn t have an understanding of tagged frame the column fi...

Страница 81: ...ances security between customer each home by dis communication between the sub VLANs even they are located in the same LAN and have the same IP subnet mask Better yet the configuration is simple than assigning each VLAN as per port based VLAN to customer each home Note 1 It s not necessary to type 1 in the tagged VID The hybrid port will forward the frames of VLAN 1 2 The trunk port has to be conn...

Страница 82: ...75 6 24 2Switch Status You can see the status of VLAN setting in this function ...

Страница 83: ...hoose to use an 8 4 2 1 queuing scheme or a strict priority scheme or select the priority type to configure QoS policy Qos Policy Select the QoS policy rule Using the 8 4 2 1 weight fair queue scheme The switch will follow 8 4 2 1 rate to process priority queue from High to lowest queue For example while the system processing 1 frame of the lowest queue 2 frames of the low queue 4 frames of the mi...

Страница 84: ...down selection item of Priority Type above being selected as Port based this control item will then be available to set the queuing policy for each port Port x Each port has 4 priority levels High Middle Low and Lowest to be chosen Click Apply to have the configuration take effect ...

Страница 85: ...el With the drop down selection item of Priority Type above being selected as COS only COS first this control item will then be available to set the queuing policy for each port COS priority Set up the COS priority level 0 7 High Middle Low Lowest Click Apply ...

Страница 86: ...des 0 63 DSCP priority level Each level has 4 types of priority High Middle Low and Lowest The default value is Lowest priority for each level When the IP packet is received the system will check the DSCP level value in the IP packet that has received For example the user sets the DSCP level 25 as high the system will check the DSCP value of the received IP packet If the DSCP value of received IP ...

Страница 87: ...80 highest priority Click Apply to have the configuration take effect ...

Страница 88: ...rt can be selected to be destination mirror port for monitoring both RX and TX traffic which come from source port Or use one of two ports for monitoring RX traffic only and the other one for TX traffic only User can connect mirror port to LAN analyzer or Netxray Source Port The ports that user wants to monitor All monitored port traffic will be copied to mirror destination port User can select mu...

Страница 89: ...heckboxes and the ten security IP column fields will then be available If not those items will appear in grey Enable HTTP Server Having ticked this checkbox the devices whose IP addresses match any one of the ten IP addresses in the Security IP1 IP10 table will be given the permission to access this switch via HTTP service Enable Telnet Server Having ticked this checkbox the devices whose IP addre...

Страница 90: ...or access security Only these 10 IP addresses can access and manage the switch through the HTTP Telnet service once IP Security Mode is enabled And then click Apply to have the configuration take effect NOTE Remember to execute the Save Configuration action otherwise the new configuration will lose when the switch powers off ...

Страница 91: ... the specified RADIUS Server Shared Key Set an encryption key for using during authentication sessions with the specified RADIUS server This key must match the encryption key used on the RADIUS Server NAS Identifier Set the identifier for the RADIUS client Quiet Period Set the period which the port doesn t try to acquire a supplicant TX Period Set the period the port waits for retransmit next EAPO...

Страница 92: ...eld in the unauthorized state Accept The specified port is required to be held in the authorized state Authorize The specified port is set to the Authorized or Unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server Disable When disabled the specified port works without complying with 802 1x protocol Click Apply ...

Страница 93: ...86 6 26 3 3 Port Status You can monitor the port Authorized state in this function ...

Страница 94: ...87 6 26 4 MAC Filtering You can block the un authorized MAC by switch in this function ...

Страница 95: ...88 6 26 5 Port Security You can block the un authorized MAC by oer port in this function ...

Страница 96: ...1 Save Configuration Save the current setting of switch 6 27 2 Restart Device Make the switch warm start 6 27 3 Factory Defaults Reset switch to default configuration Click Reset to reset all configurations to the default value ...

Страница 97: ...e Upgrade TFTP Server IP Address Type in your TFTP server IP Firmware File Name Type in the name of the firmware image file to be updated Click Upgrade You can also browser the firmware on your hard drive by web update ...

Страница 98: ...Server IP Address Type in the TFTP server IP Restore File Name Type in the correct file name for restoring Click Restore You can back up the current configuration from flash ROM to the TFTP server for the purpose of recovering the configuration later It helps you to avoid wasting time on configuring the settings by backing up the configuration TFTP Server IP Address Type in the TFTP server IP Back...

Страница 99: ...o Specify the SFP port and show the SFP module information Temperature Display the internal temperature of the SFP default threshold and present value Vcc Display the supply voltage of the SFP default threshold and present value Tx Bias Display the Bias current of the SFP default threshold and present value ...

Страница 100: ...r of the SFP default threshold and present value RX PWR Display the received power of the SFP default threshold and present value Syslog SMTP The port will send an e mail or log on local to administrator when detecting the exceptional value ...

Страница 101: ...he length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutions If the power indicator does not light on when the power cord is plugged in you may have a problem with...

Страница 102: ...nd crossover cable schematic 10 100BASE TX Pin outs With10 100BASE TX cable pins 1 and 2 are used for transmitting data and pins 3 and 6 for receiving data RJ 45 Pin Assignments Pin Number Assignment 1 Tx 2 Tx 3 Rx 6 Rx NOTE and signs represent the polarity of the wires that make up each wire pair The table below shows the 10 100BASE TX MDI and MDI X port pin outs Pin Number MDI X Signal Name MDI ...

Страница 103: ...ing two figures show the 10 100Base TX cable schematic Straight through cable schematic Cross over cable schematic 10 100 1000Base TX Pin outs The following figure shows the 10 100 1000 Ethernet RJ 45 pin outs 10 100 1000Base TX Cable Schematic ...

Страница 104: ...97 Straight through cables schematic Cross over cables schematic ...

Страница 105: ...transmitting data and pins 3 and 6 for receiving data pins 4 5 7 and 8 are used for power supplying Pin out of Cisco non 802 3af standard PD Pin Signal 1 RX 2 RX 3 TX 4 VCC 5 VCC 6 TX 7 VCC 8 VCC Pin out of PoE Midspan Hub Switch Pin Signal Name 1 RX 2 RX 3 TX 4 VCC 5 VCC 6 TX 7 VCC 8 VCC ...

Страница 106: ...TX VCC 7 8 Note and signs represent the polarity of the wires that make up each wire pair Before you power PD please check the RJ 45 connector pin assignment follow IEEE802 3af standard otherwise you may need to change one of the RJ 45 connector pin assignment attached with the UTP cable ...

Страница 107: ...time switch uptime disable P Leave Privileged EXEC mode switch enable switch disable configure P Enter Global configuration mode switch enable switch configure end G Leave Global configuration mode switch enable switch config end exit G Leave Global configuration mode switch enable switch config exit Switch Setting Commands Set Netstar Commands Level Description Example show terminal P Show consol...

Страница 108: ...witch show system info Admin Password Commands Set Netstar Commands Level Description Example admin username Username G Changes a login username maximum 10 words switch enable switch configure switch config admin username xxxxxx admin password Password G Specifies a password maximum 10 words switch enable switch configure switch config admin password xxxxxx show admin P Show administrator informat...

Страница 109: ... sntp enable sntp ip IP G Set SNTP server IP if SNTP function is inactive this command can t be applied switch enable switch configure switch config sntp ip 192 168 16 1 sntp timezone Timezone Format 1 63 G Set timezone index use show sntp timzezone command to get more information of index number switch enable switch configure switch config sntp timezone 22 sntp daylight G Enable daylight saving t...

Страница 110: ...index number of time zone list switch enable switch show sntp timezone no sntp G Disable SNTP function switch enable switch configure switch config no sntp no sntp daylight G Disable daylight saving time switch enable switch configure switch config no sntp daylight LLDP Commands Set Netstar Commands Level Description Example lldp enable G Enable LLDP function switch enable switch configure switch ...

Страница 111: ...ify the IP of TFTP server and the file name of image switch enable switch configure switch config tftp 192 168 16 120 restore 123 bin Upgrade Firmware Commands Set Netstar Commands Level Description Defaults Example tftp server IP upgrade file name G Upgrade firmware by TFTP and need to specify the IP of TFTP server and the file name of image switch enable switch configure switch config tftp 192 1...

Страница 112: ...ure DNS IP for DHCP clients switch enable switch configure switch config dhcpserver dnsip 192 168 1 1 dhcpserver leasetime Hours G Configure lease time Hours switch enable switch configure switch config dhcpserver leasetime 1 dhcpserver ipbinding IP address I Set static IP for DHCP clients by port switch enable switch configure switch config interface fastEthernet 2 switch config if dhcpserver ipb...

Страница 113: ...e of operation for Ethernet ports Use the disable form of this command to disable the port switch enable switch configure switch config interface fastEthernet 2 switch config if state disable duplex full half I Use the duplex configuration command to specify the duplex mode of operation for Fast Ethernet switch enable switch configure switch config interface fastEthernet 2 switch config if duplex ...

Страница 114: ...nable switch configure switch config interface fastEthernet 2 switch config if security enable no security I Disable security of interface switch enable switch configure switch config interface fastEthernet 2 switch config if no security auto sfp Enable Disable G Enable disable to auto detect 100 1000 SFP switch enable switch configure switch config auto sfp disable alias name I Set port alias nam...

Страница 115: ...able switch configure switch config interface fastEthernet 2 switch config if ratelimit type all ratelimit type broadcast multicast flooded unicast I Set interface ingress limit frame type to accept broadcast multicast and flooded unicast frame switch enable switch configure switch config interface fastEthernet 2 switch config if ratelimit type broadcast multicast flooded unicast ratelimit type br...

Страница 116: ...ero means no limit switch enable switch configure switch config interface fastEthernet 2 switch config if ratelimit out 160 show ratelimit I Show interfaces bandwidth control switch enable switch configure switch config interface fastEthernet 2 switch config if show ratelimit Trunk Commands Set Netstar Commands Level Description Example aggregator priority 1 65535 G Set port group system priority ...

Страница 117: ...port 1 2 aggregator group GroupID Port list nolacp G Assign a static trunk group GroupID 1 3 Port list Member port list This parameter could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 switch enable switch configure switch config aggregator group 1 2 4 nolacp or switch config aggregator group 1 3 1 2 nolacp show aggregator P Show the information of trunk group switch enable ...

Страница 118: ...backup G Configure PRO RING IIS ROOT switch enable switch configure switch config prorstp root enable no prorstp I Disable PRO RING IIS for this interface switch enable switch configure switch config interface fastEthernet 2 switch config if no prorstp no prorstp G Disable PRO RING IIS for all interfaces switch enable switch configure switch config no prorstp show prorstp P Show PRO RING IIS confi...

Страница 119: ...igure switch config rstp forward time 4 rstp path cost 0 auto 1 200000000 I Path cost on this interface switch enable switch configure switch config interface fastEthernet 2 switch config if rstp path cost 20 rstp port priority 0 240 I Port priority on this interface switch enable switch configure switch config interface fastEthernet 2 switch config if rstp port priority 16 rstp admin p2p Auto Tru...

Страница 120: ...nfig no rstp VLAN Commands Set Netstar Commands Level Description Example vlan database P Enter VLAN configure mode switch enable switch vlan database vlanmode portbase 802 1q diable gvrp V To set switch VLAN mode switch enable switch vlan database switch vlan vlanmode portbase or switch vlan vlanmode 802 1q or switch vlan vlanmode disable or switch vlan vlanmode gvrp Ported based VLAN configurati...

Страница 121: ...be applied switch enable switch vlan database switch vlan vlan 8021q name test vid 22 vlan 8021q port PortNumber access link untag UntaggedVID V Assign a access link for VLAN by port if the port belong to a trunk group this command can t be applied switch enable switch vlan database switch vlan vlan 8021q port 3 access link untag 22 vlan 8021q port PortNumber trunk link tag TaggedVID List V Assign...

Страница 122: ... 5 tag 6 8 vlan 8021q aggreator PortNumber access link untag UntaggedVID V Assign a access link for VLAN by trunk group switch enable switch vlan database switch vlan vlan 8021q aggreator 3 access link untag 33 vlan 8021q aggreator PortNumber trunk link tag TaggedVID List V Assign a trunk link for VLAN by trunk group switch enable switch vlan database switch vlan vlan 8021q aggreator 3 trunk link ...

Страница 123: ...rt base group ID switch enable switch vlan database switch vlan no vlan 2 SNMP Commands Set Netstar Commands Level Description Example snmp agent mode v1v2c v3 G Select the agent mode of SNMP switch enable switch configure switch config snmp agent mode v1v2c snmp community strings Community right RO RW G Add SNMP community string switch enable switch configure switch config snmp community strings ...

Страница 124: ...r password Authentication Password Privacy Password G Remove SNMPv3 user profile switch enable switch configure switch config no snmp snmpv3 user root password 123 123 Traffic Prioritization Commands Set Netstar Commands Level Description Example qos prioritytype port based cos only tos only cos first tos first G Setting of QOS priority type switch enable switch configure switch config qos priorit...

Страница 125: ...ation switch enable switch configure switch show qos no qos G Disable QoS function switch enable switch configure switch config no qos IGMP Commands Set Netstar Commands Level Description Example igmp enable G Enable IGMP snooping function switch enable switch configure switch config igmp enable igmp query auto fource G Configure IGMP query mode switch enable switch configure switch config igmp qu...

Страница 126: ...itch show igmp configuration show igmp table P Show IGMP snooping table switch enable switch show igmp table no igmp G Disable IGMP snooping function switch enable switch configure switch config no igmp no igmp query G Disable IGMP query switch enable switch configure switch config no igmp query Multicast Static Filtering Table Commands Set Netstar Commands Level Description Example multicast filt...

Страница 127: ...lnet server switch enable switch configure switch config security telnet security snmp G Enable IP security of SNMP server switch enable switch configure switch config security snmp security ip Index 1 10 IP Address G Set the IP security list switch enable switch configure switch config security ip 1 192 168 1 55 show security P Show the information of IP security switch enable switch show securit...

Страница 128: ... switch enable switch show mac address table static no mac address table static hwaddr HW Addr I Remove an entry of MAC address table of interface static switch enable switch configure switch config interface fastEthernet 2 switch config if no mac address table static hwaddr 000012345678 MAC Blacklist Commands Set Netstar Commands Level Description Example mac address table filter hwaddr HW Addr G...

Страница 129: ...he 802 1x system server port global configuration command to change the radius server port switch enable switch configure switch config 8021x system serverport 1815 8021x system accountport Port Number G Use the 802 1x system account port global configuration command to change the accounting port switch enable switch configure switch config 8021x system accountport 1816 8021x system sharedkey Shar...

Страница 130: ...tch configure switch config 8021x misc supptimeout 20 8021x misc servertimeout Seconds G Use the 802 1x misc server timeout global configuration command to set the server timeout switch enable switch configure switch config 8021x misc servertimeout 20 8021x misc maxrequest number G Use the 802 1x misc max request global configuration command to set the MAX requests switch enable switch configure s...

Страница 131: ...e Relay Alarm for Power Failure switch enable switch configure switch config fault relay power 1 enable fault relay enable disable I Configure Relay Alarm for Port Link Down Broken switch enable switch configure switch config interface fastEthernet 1 switch config if fault relay enable show fault relay P Show Fault Relay Alarm setting switch enable switch show fault relay no fault relay G Disable ...

Страница 132: ... config smtp enable smtp serverip IP address G Configure SMTP server IP switch enable switch configure switch config smtp serverip 192 168 1 5 smtp sender sendername G Configure sender of mail switch enable switch configure switch config smtp sender test01 smtp subject subject G Configure subject of mail switch enable switch configure switch config smtp subject alarm smtp authentication G Enable S...

Страница 133: ...nt device restart Syslog SMTP Both G Set device restart event type switch enable switch configure switch config event device restart both event authentication failure Sysog SMTP Both G Set Authentication failure event type switch enable switch configure switch config event authentication failure both event syslog Link UP Link Down Both I Set port event for SYSLOG switch enable switch configure swi...

Страница 134: ...e switch configure switch config interface fastethernet 3 switch config if no event syslog no event smpt I Disable port event for SMTP switch enable switch configure switch config interface fastethernet 3 switch config if no event smtp Mac Address Table Commands Set Netstar Commands Level Description Example show mac address table I Show MAC address table switch enable switch configure switch conf...

Страница 135: ...switch configure switch config interface fastEthernet 2 switch switch config if show interface accounting no accounting I Clear interface accounting information switch enable switch configure switch config interface fastEthernet 2 switch config if no accounting Port Monitoring Commands Set Netstar Commands Level Description Example monitor destination RX TX Both I Configure destination port of mon...

Страница 136: ...tEthernet 2 switch config if no monitor System Event Log Commands Set Netstar Commands Level Description Example show syslog P Show SYSLOG configuration and log table switch enable switch show syslog Ping Commands Set Netstar Commands Level Description Example ping ip E Ping function switch ping 192 168 16 1 SFP Monitor Commands Set Netstar Commands Level Description Example show ddm P Show temper...

Страница 137: ...ect Enable Disable P Set PoE system AC Disconnect switch enable switch poe switch poe system ac disconnect enable system capacitive detect Enable Disable P Set PoE system Capacitive Detection switch enable switch poe switch poe system capacitive detect enable port PortNumbers powerlimit Value P Set Poe system Power Limit switch enable switch poe switch poe port 1 powerlimit 11000 port PortNumbers ...

Страница 138: ...bers schedule enable P Set PoE schedule Configuration switch enable switch poe switch poe port 1 schedule enable port PortNumbers schedule day 0 6 e g 0 Sun 6 Sat hour 0 23 power On Down P Set PoE schedule date day switch enable switch poe switch poe port 1 schedule day 5 hour 21 power on switch poe port 1 schedule day 0 1 hour 0 3 power on switch poe port 1 schedule day 0 4 hour 0 3 5 power on sh...

Страница 139: ...Netstar Commands Level Description Example default keepip keepadmin both G Restore to factory default configuration switch enable switch configure switch config default both System Reboot Commands Set Netstar Commands Level Description Example reload G Reboot switch switch enable switch configure switch config reload Logout Commands Set Netstar Commands Level Description Example logout E Logout co...

Отзывы: