38
6.8.2 System Alert - Event
Having ticked the
Syslog
/
SMTP
checkboxes, the event log/email alert will be sent to the
system log server and the SMTP server respectively. Also, Port event log/alert (link up,
link down, and both) can be sent to the system log server/SMTP server respectively by
setting the trigger condition.
System event selection:
There are 3 event types
—Device Cold Start,
Authentication Failure, and X-ring Topology Change. The checkboxes are not
available for ticking unless the
Syslog Client Mode
on the Syslog Configuration tab
and the
E-mail Alert
on the SMTP Configuration tab are enabled first.
System Restart:
When the device executes cold start action, the system will
issue the event log/email alert to the system log/SMTP server respectively.
Power Status:
When the power consumption about PoE was unstable, he
system will issue the event log/email alert to the system log/SMTP server
Содержание IES-2008B-DNV
Страница 1: ...Lantech IES 2008B DNV 8 10 100TX Managed Industrial Switch User Manual V2 01 Jul 2016...
Страница 32: ...25...
Страница 38: ...31 IP Addressing interface...
Страница 41: ...34 SNMP Agent Configuration interface...
Страница 49: ...42...
Страница 51: ...44 6 13 Port Status It will show you the status of port configuration setting...
Страница 53: ...46 Port Statistics interface...
Страница 59: ...52 Port Trunk Aggregator Setting interface four ports are added to the left field with LACP enabled...
Страница 60: ...53 6 17 2Aggregator Status You can check the setting of Port aggregation in Status...
Страница 67: ...60 field and click Delete to remove it...
Страница 69: ...62 6 22 1 LLDP Neighbors It will show you the information about Port Neighbor via LLDP protocol...
Страница 71: ...64 You can monitor the learning status of MAC address table in this function...
Страница 75: ...68 6 24 2Switch Status You can see the status of VLAN setting in this function...
Страница 80: ...73 highest priority Click Apply to have the configuration take effect...
Страница 86: ...79 6 26 3 3 Port Status You can monitor the port Authorized state in this function...
Страница 87: ...80 6 26 4 MAC Filtering You can block the un authorized MAC by switch in this function...
Страница 88: ...81 6 26 5 Port Security You can block the un authorized MAC by oer port in this function...
Страница 92: ...85 6 27 6 Diagnostics 6 27 6 1 Ping You can ping other network device in this function...