13
6.6
Injecting the sealing foam
Fig. 21
Note:
- Reconfiguration is no longer possible
after filling with foam!
- Use a suitable cartridge gun or
alternatively
an adapter (see chapter 6.8) for the
cartridge
(2)
.
Observe the expiry date! Refer to the
cartridge label.
•
Put on work gloves.
•
Place the cartridge
(2)
in the cartridge
gun
(3)
.
•
Screw on the mixing nozzle
(1)
.
•
Fill the mixing nozzle using the cartridge
gun.
•
Squirt the next two strokes into the
packaging bag.
Fig. 22
•
Insert the mixing nozzle
(1)
into the
backfill opening
(2)
.
•
Inject the L100 sealing foam and always
empty the cartridge completely
.
•
Leave the mixing nozzle with cartridge
in the backfill opening for a few minutes
(for disposal, see section 11).
1
2
1
2