5. Operating modes
The EK 533 plus 2.0 pedestrian signal requesting device for the visually impaired has several
operating modes, allowing it to be used as flexibly as possible.
The relevant operating voltage must be selected in cgManager (see Fig. 66). Jumper position
(see Fig. 9).
Each mode has requirements for:
• Connecting the device to the control unit
• Software parameters
• Device hardware modifications (buffer PCB)
• When the operating voltage is
applied, the device is in initialisation
mode.
• The current operating mode is
displayed after the green signal is
activated for the first time.
Operating mode
Jumper
connected
Goldcap
buffer PCB
Parametrisatio
n required
Notes
P mode
-
-
-
PR mode
-
-
OPT3 = Red signal
1
PRF mode
-
-
FRS active,
OPT3 = Red
signal
1; 2
RG mode
Yes
-
-
1
RGF mode
Yes
Yes
FRS active
1; 2
1
Should not be used in Germany
2
Flashing mode does not conform to DIN 32981
Once the device is switched on, the operating voltage must be defined in cgManager. The device
is internally ready for operation. When the device detects overvoltage/undervoltage, it switches off
all tactile and acoustic signals. The device cannot be damaged by applying a higher/lower voltage
than the one in the settings. (See Page 42, Fig. 66.)