40
Example 1:
"Mode" is "Flashing 1 Hz" and activation is "APB": When a button is pressed during the red phase,
the device starts flashing. It stops flashing when the signal changes to the green phase.
Example 2:
"Mode" is "Flashing 1 Hz" and activation is "iAPB": When a button is pressed during the red phase,
the device stops flashing. It starts flashing when the signal changes to the green phase.
Example 3:
"Mode" is "Flashing 1 Hz", activation is "APBS", "Time to ack. (s)" is "3" and
"Logic type input" is "high": When a button is pressed during the red phase, the device starts
flashing. If there is a high level on the feedback input within three seconds, the device goes on
flashing for as long as that level is sustained. If there is no high level on the feedback input within
three seconds, the flashing stops after the three seconds have elapsed. The flashing always stops
when the signal changes to the green phase.
Example 4:
"Mode" is "Flashing 1 Hz" and activation is "APBI": When a button is pressed during the red
phase, the device starts flashing. It stops flashing when the signal changes to the green phase.
The device also starts flashing if there is a signal on the feedback input originating from an output
of an EK 533 plus connected via networking, for example.
Time to ack. (s)
• This determines the time within which the signal system must send the level signal set under
"Logic type input" in order to keep optical feedback active on the feedback input when the
"APBS" option is selected under "Activation".
• Restriction: Input is only possible if "APBS" is selected under "Activation".