35
Time
• Selecting the "time controlled" option in
"Control" on a Langmatz EK 533 plus
fitted with an RTC allows you to define
the period when the sound is to be
(de)activated.
Fig.
54
"Outputs" tab
• In this tab, you can configure the
switching
outputs.
PB/S (ms)
• Determines how long a pulse is emitted
on the output concerned when the large-
surface push-button or large-surface
sensor has been pressed.
Fig.
55
VPB (ms)
• Determines how long a pulse is emitted
on the output concerned when the
vibrator push-button has been pressed.
Logic type
• "Turnkey"/
"N.
Closed" setting option based
on the required output logic.
Fig.
56
Important note:
The release signal must be activated and deactivated in compliance with DIN 32981.
This is carried out by the control unit of the road traffic signal system.
If shut-off or reduction is performed by the RTC of the EK533 plus, the change will only
become effective during the next green phase.