33
Logic type
• Setting option "low" or "high" based on
the required logic for the optional input.
• Restriction: This value can only be set if
an optional input has been selected for
"Input". (In other words, "inactive" is not
selected here.)
Fig.
48
Time
• Selecting the "time controlled" option in
"Control" on an EK 533 plus with RTC
allows you to define the period when the
sound is to be reduced.
Fig.
49
"(De)Activation" group
Fig.
50
• This parameter group specifies the additional conditions that may be required to
play the sound in question.
Control
Fig.
51
Specifies how (de)activation is controlled:
• "deactivated": No (de)activation
• Opt. 1: The sound is (de)activated by
optional input 1.
• Opt. 2: The sound is (de)activated by
optional input 2.
• Opt. 3: The sound is (de)activated by
optional input 3.
• "time controlled": The RTC controls
(de)activation.