30
Green flashing
Switches green flashing "on" or "off". When the green flashing function is activated, a green
flashing sound must also be present in the Langmatz EK 533 plus. (You can check this using the
"Edit" -> "Audio sequences" -> "online" menu.)
• RGF mode requires a Goldcap buffer
PCB.
This is available as an option or can be
retrofitted. Item no. 125330825.
Fig.
44
"Volume" group
This parameter group determines the
volume and dynamics of the sound in
question.
Fig.
45
Current max. level (dB)
• This is purely a display parameter; it
cannot be changed by the user. It
indicates the current maximum level
based on whether any restrictions have
been set.
• In daytime mode, the value is always the
same as that of the "Level max. (dB)"
parameter. In night-time mode, it is the
reduced maximum level, which is "Level
max. (dB)" minus "Level (dB)".
• Example: Night-time reduction active,
"Level max. (dB)" at 85 and reduction
"Level (dB)" at 35. This reduces the
"Level max. current (dB)" to 50, i.e.
85 dB reduced by 35 dB.
Level min. (dB)
• The minimum level sets the lower signal
volume limit within a range of 30 to
85 dB.