6.2 Aligning the crossing symbol
• The pedestrian signal requesting device
for the visually impaired is factory-fitted
with a crossing symbol
(6)
.
• If the specified direction of the
crossing symbol does not match the
direction required, proceed as
follows:
Fig.
16
• Open the white brackets
(7)
with
the special key supplied
(8)
.
• Push in the crossing symbol slightly (to
disengage it) and turn it in the required
direction.
• Make sure that the integrated spring
does not come out.
• Remove the special key
(8)
.
• Release the crossing symbol and re-
engage it.
• Make sure that the integrated silicone
seal
(9)
fits correctly.
Fig.
17
Fig. 18
• Before installing the top part of the
device
(3)
, you need to install the relief
symbol inserts (accessories kit) based
on the circumstances of the crossing
(see Section 6.3).
• Reconnect the supply line for
the top part of the device
(Fig. 15, 4).
• After inserting the relief symbols,
push the top part of the device
(3)
onto the bottom part
(10)
.
• Check that it fits correctly and securely.
• Tighten the SW4 hexagon socket
locking screws
(2)
.
6
3
10
2