• Disconnect the supply line for the top
part of the device by releasing the
connector lock
(4)
.
• Fasten the bottom part of the device to
the pole using the pre-installed,
stainless-steel lighting-pole adaptor
and flexible pole seal (M6 x 25 A2
screws supplied).
• Note:
For poles > 159 mm in diameter,
use the optional lighting-pole adaptor
for large poles. For wall installation,
use the appropriate wall adapter.
• Note:
Torque approx. 5
Nm.
• Note:
The flexible silicone pole seal
must fit correctly between the pole
and the signal requesting device.
• Place the captive plastic caps
(5)
back
on both M6
fastening screws.
Make sure that the
device fits correctly (protection
class!).
• Connect the connection cable to the
cable distributor according to the block
diagram (see Section 4.6).
• Unused cores must remain
insulated.
• After installing the pedestrian signal
requesting device for the visually
impaired, a function test must be
performed:
Green = Release signal
Red = Orientation sound
You must be able to tell the two
sounds apart clearly.