LANGER EMV-Technik NNB 21 Скачать руководство пользователя страница 5

 

LANGER 

EMV-Technik 

 
 
 
 

 

DE-01728 Bannewitz 
[email protected] 
www.langer-emv.com 

NNB 21 set 

3  Scope of Delivery 

Item 

Designation 

Type 

Qty. 

--------------------------------------------------------------------------------------------------------------------------------- 

01 

Line impedance stabilisation network

 

NNB 21

 

02 

Measurement cable

 

SMB-BNC 1 m

 

03 

Terminal block, 2-polie

 

AK 2 pole

 

04 

User manual

 

NNB 21 m

 

05 

System Case 

NNB 21 case 

 
Important:

 The scope of delivery may differ depending on the respective order. 

 

 

 

Figure 1: NNB 21 set case 

 

4  Technical Parameters 

RF-Path 

Measuring channels 

2, one path can be deactivated 

Frequency range 

100 kHz 

– 1 GHz 

Internal damping 

10 dB 

 

Board networks path 

Max. continuous current 

10 A 

Max. operating voltage 

50 V 

DC resistance 

< 20 m

 

Содержание NNB 21

Страница 1: ..._NNB 21 set_user manual User Manual NNB 21 set Line impedance Stabilization Network Measurement of conducted disturbance emissions Copyright C Dipl Ing Gunter Langer N thnitzer Hang 31 01728 Bannewitz...

Страница 2: ...Reading and Understanding the Manual 4 2 3 Local Safety and Accident Prevention Regulations 4 2 4 Images 4 2 5 Limitations of Liability 4 2 6 Errors and Omissions 4 2 7 Copyright 4 3 Scope of Deliver...

Страница 3: ...nce Stabilization Network agrees with the regulations of EC guidelines Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU Restriction of certain Hazardous Substances 2011 65 EU Applied standard...

Страница 4: ...lity The Langer EMV Technik GmbH is not liable for personal injury or damage to material if the instructions in this user manual were not followed the product was used by personnel who are not qualifi...

Страница 5: ...3 Terminal block 2 polie AK 2 pole 4 04 User manual NNB 21 m 1 05 System Case NNB 21 case 1 Important The scope of delivery may differ depending on the respective order Figure 1 NNB 21 set case 4 Tech...

Страница 6: ...H carry out a visual inspection Damaged connecting cables must be replaced before operation The product of Langer EMV Technik GmbH may only be used for applications for which it is intended Any other...

Страница 7: ...it frequency of 1 GHz less than 5 cm If both connections of the NNB 21 are used to supply the DUT and the GND switch is open the NNB 21 measures the total current common mode of both lines For a separ...

Страница 8: ...processed either in its entirety or in part without the prior written permission of Langer EMV Technik GmbH The management of Langer EMV Technik GmbH assumes no liability for damage that may arise fro...

Отзывы: