REAR PANEL CONTROLS

EFFECTS LOOP RETURN:

  Connect the output from your external effects to this socket. 

control 

allowing you to make up for any insertion loss that may occur in the FX processor. Use this mode when the whole of the 
amplifier signal needs routing through any external processors such as graphic EQs etc.

Warning: In insert mode with the FX return level control at minimum the amplifier will have no output,  a good 

normal level for this control is ‘5’ which is approx unity gain.

3) Bypass:

 The global FX loop circuitry is switched out of circuit altogether.

EFFECTS LOOP SWITCH:

  This allows the global effects loop to operate in three distinct modes:

1) Side Chain: 

 The return signal is mixed with the dry signal, the level of FX return is controlled by the FX return level 

control. This allows you to set the right mix between the dry signal and the effects signal. Use Side chain mode for FX units 
such as delays, flangers etc where a direct signal path is maintained internally to avoid loss of dynamics through the external 
FX processor.  When using this mode the external FX processor should be switched to ‘effect only mode’

2) Insert: 

 The return signal is buffered and sent directly to the output tubes, no mixing with the dry signal happens.The 

wet/dry mix is adjusted within the external FX processor. The FX return level control then acts as overall level 

FX SEND: 

1/4" mono jack socket for connection to the input of an external FX unit. This can also be used as a line out for 

connection to another power amp slave input or for recording.

FOOTSWITCH CONNECTIONS:

 The TI100 is equipped with a 5 pin DIN socket for the connection of the supplied FS4-

TI footswitch, allowing remote operation of the following functions: Channel, Lead Boost on/off & Rhythm Boost on/off.

1/4" 

1/4" 

LOUDSPEAKER CONNECTIONS 

Five 1/4" mono jack sockets are provided for the connection of a variety of speaker 

cabinets. Mismatching your speaker impedance will reduce the performance of your amplifier, and in extreme cases may 
damage the unit.  Never operate any tube amplifier without a load connected: serious irreparable damage may occur.

SYM LINK: 

Link sockets are used when connecting two or more amplifiers together with a single master amplifier. The 

connection ensures that the slave amplifiers change channels synchronised to the master amplifier. This enables the 
Presence and Enhance controls on the slave amplifiers to be synchronised with the master amplifier.

SYM OUT: 

Connect a 

mono jack lead from here to a slave amplifier to ensure channel synchronisation.

SYM IN: 

Connect a 

mono jack lead from a master amplifier to ensure channel synchronisation.

Содержание Iommi TI100

Страница 1: ......

Страница 2: ...wires in the mains lead of this unit do not correspond with the terminals in your plug proceed as follows a The wire that is coloured green and yellow must be connected to the terminal that is marked...

Страница 3: ...contr ler votre unit Celle ci doit tre contr l e si elle a subit des dommages de manipulation d utilisation ou de stockage humidit 15 Ne d connectez jamais la prise de terre de votre unit 16 Si votre...

Страница 4: ...chnitte 14 Lassen Sie s mtliche Wartungsarbeiten von qualifizierten Kundendiensttechnikern durchf hren Eine Wartung ist erforderlich wenn das Ger t in irgendeiner Art besch digt wurde etwa wenn das Ne...

Страница 5: ...ble de alimentaci n o el enchufe se han da ado alg n l quido ha sido derramado o alg n objeto ha ca do dentro del aparato el aparato ha sido expuesto a la lluvia o la humedad no funciona de manera nor...

Страница 6: ......

Страница 7: ...nternal Glow Sym Link Sockets HT Fuse 25 5Kg 100V 120V 220V 230V 240V 50 60Hz Packed Weight 271 678 288 H W D 21 5Kg TI412S Recommended Ex Cabinet Size Yes Comfortable 90 top mounted Volume Independen...

Страница 8: ......

Страница 9: ...sociation with Tony Iommi and very happy to be able to announce a new Tony Iommi signature amp the TI100 Tony Iommi s TI100 is a leap forward in guitar tone Born out of an exhaustive period of product...

Страница 10: ...ore distortion This works on both channels PRE BOOST CONTROL Controls the level of boost applied to the guitar signal PRE BOOST LED This LED will illuminate when the Pre Boost controls are activated D...

Страница 11: ...the amp is in play mode while 0 down allows the amp to warm up STANDBY LAMP This will illuminate when the amplifier is in play mode POWER SWITCH Main power switch for the unit Tube amplifiers take be...

Страница 12: ...is allows the use of either 6L6 or EL34 output tubes in your amplifier Ensure that the switch is in the correct position for your output tubes otherwise you may risk damaging your amplifier The TI100...

Страница 13: ...ng with the dry signal happens The wet dry mix is adjusted within the external FX processor The FX return level control then acts as overall level FX SEND 1 4 mono jack socket for connection to the in...

Страница 14: ...QUICK START SETTINGS USE EITHER CHANNEL CLEAN CRUNCH LEAD 1 3 VOLUME AS DESIRED TONY S TYPICAL SETTINGS...

Страница 15: ...USER SETTINGS ON ON OFF OFF L R ON ON OFF OFF L R ON ON OFF OFF L R ON ON OFF OFF L R...

Страница 16: ...hard and how often it is played vibration due to travel etc Tubes should be changed in your amplifier if you notice any deterioration in your amplifiers sound or performance Otherwise they need not be...

Страница 17: ...N SIDE CHAIN MODE SYM LINK OUT SYM LINK IN FOOTSWITCH LEAD EQ RHYTHM EQ BASS BASS MID MID TREBLE TREBLE LEAD VOLUME FX LEVEL RHYTHM VOLUME CHANNEL SWITCH LEAD DRIVE RHYTHM DRIVE 8Ohms 2x16Ohms 4Ohms 2...

Страница 18: ...SAMPLE SETUPS FX Unit FS4 TI L Z B1 2 3 4 L Z B1 2 3 4 TI412S...

Страница 19: ...X Unit L Z B1 2 3 4 L Z B1 2 3 4 L Z B1 2 3 4 Master Master FS4 TI TI412S TI412S Slave All of the preamp controls are disabled on the Slave amp only the Dynamics Presence controls are operational See...

Страница 20: ...OPERATING INSTRUCTIONS Issue 1 3...

Отзывы: