background image

Surface Mount

Tools Required

Safety glasses

Screwdrivers

Wiring tools and connectors

1/2” wrench or socket

Hammer drill, with 1/2” dia bit

2mm hex key

Epoxy anchoring system for concrete

Wire brush and compressed air for clearing anchor holes

Standard octagon junction box, installed (not included)

ASSEMBLE WITH CARE!

Pangard II

Polyester Powdercoat is a strong, long-lasting finish.  To protect this finish 

during assembly, place unwrapped powdercoated parts on packaging foam or other non-marring surface.  Do not 

place or slide powdercoated parts on concrete or other hard or textured surface – this will damage the finish 

causing rust to occur.  Use touch-up paint on any gouges in the finish caused by assembly tools.

LIGHTING LAYOUT RECOMMENDATIONS:

Path light spacing is the responsibility of others. Refer to the Motive Path Light 

Product Data Sheet, available on 

www.landscapeforms.com

, for light 

distribution options.

Installation Guide

Motive

Path Light

www.landscapeforms.com      Ph: 800.521.2546

Date: November 19, 2019

Page 1 of 3

Fig. 3 – Base plate detail

[133mm]

Ø5-1/4”

BOLT CIRCLE    

FRONT 

OF LIGHT

Fig. 1 – Minimum footing recommendation

2-1/2”MAX

RECOMMENDED 

CONDUIT CLEARANCE

1/2” – 3/4”

RECOMMENDED

CONDUIT SIZE

Included hardware

4x – concrete

anchor

4x – 5/16 

washer

1x – path light 

assembly

4x – 5/16-18 x 

1” hex hd bolt

1x – anchor

template

Fig. 2 – Recommended setback 

from sidewalk

SIDEWALK 