3-16
9K998
OPERATION
Acre Meter - Optional
Settings for Loup Acre Meters
After 05/15/2012
The battery operated acre counter operates in one of two
modes. In sleep mode, the display is blank, and the
counter is accumulating acres. Sleep mode will be
entered if a button is not pressed for 20 seconds. In entry
mode, the display is on, and the operator can enter
values. To get into entry mode, press the
*
/FUNC
button. If you continue to press the
*
/FUNC
button, the
acre counter will cycle through the functions that it can
perform. The LEDs above the display indicate which
function is selected.
The available functions are:
Field Acres, Total Acres, Pulses per 400 ft, Width,
Password and Low Battery
Field Acres
Press the
*
/FUNC
button until the “
FIELD
” LED is lit.
The digits indicate the acres covered since the field acre
counter was cleared.
To clear the field acre count, press the
UP
and
DOWN
buttons simultaneously for two seconds. If a password
has been entered, you will not be able to clear the total
acre count. Field acres will count in tenths of an acre up
to 9999.9 acres.
Total Acres
Press the
*
/FUNC
button until the “
FIELD
” and “
TOTAL
”
LEDs are lit. The digits indicate the acres covered since
the total acre counter was cleared.
To clear the total acre count, press and hold the
UP
and
DOWN
buttons for two seconds. If a password has been
entered, you will not be able to clear the total acre count.
Total acres will count from.1 to 99999 acres.
Pulses Per 400 Feet
Press the
*
/FUNC
button until the “
PULSES
” LED is lit.
The number in the display indicates how many pulses are
generated for every 400 feet driven. There are two
methods to enter the pulses per 400 feet:
1. If you know the number, select it using the
UP
and
DOWN
buttons. When you press the
*
/FUNC
button, the Acre Counter will accept the number in
the display as the new pulses per 400 feet.
.
2. If you do not know the pulses per 400 feet, press and
hold the
UP
and
DOWN
buttons until the “0000”
appears in the display. The “
PULSES
” LED will blink.
The acre counter is now counting shaft rotations.
Enter the cab and drive 400 feet. Press the
*
/FUNC
button to wake up the acre counter. The “
PULSES
”
LED will light. The number displayed is the pulses
per 400 feet. Press the
*
/FUNC
button to accept the
setting.
If a password is set, you will not be able to adjust the
pulses.
Width
Press the
*
/FUNC
button until the “
WIDTH
” LED is lit.
The number displayed is the length of your implement in
feet.
To adjust the width, press the
UP
and
DOWN
buttons. If
a password has been entered, you will not be able to
adjust the width.
The length can be adjusted from .1 to 99.9 feet, in tenths
of a foot.
Password
The password function allows you to protect the total
acre count, pulses per 400 feet, and width settings with a
password. This stops anyone from accidentally changing
those settings. When the acre counter is shipped, the
password is disabled. You can modify the pulses per 400
feet and implement width at any time.
Press the
*
/FUNC
button until the “
PASS
” LED is lit. The
digits will display the word “
Ent
” or “
dIS
”.
If the display shows “dIS”:
The password is disabled.
The total acre count, pulses/400 feet, width, and
password settings can be adjusted using the
UP
and
DOWN
buttons. The password can also be changed
using the
UP
and
DOWN
buttons.
If the display shows “Ent”:
You must enter your
password using the
UP
and
DOWN
buttons. When your
password is displayed, press the
*
/FUNC
button to test
the password. If the password is correct, you will be able
to change the acre counter settings. The password will
be viewable until the acre counter powers down. When
the acre counter is powered up again, you will have to
re-enter the password to change settings.
If the password is not correct, you will not be able to
change the acre counter settings. When the “
PASS
”
function is selected again, “
Ent
” will appear in the
display.
Содержание BRILLION TURFMAKER II SL
Страница 2: ......
Страница 6: ...iv...
Страница 12: ...1 6 9K998 INTRODUCTION AND SAFETY INFORMATION Figure 1 4 Safety Signs 2 of 5 6 HFDOV6LQJOH R IW...
Страница 13: ...INTRODUCTION AND SAFETY INFORMATION 9K998 1 7 Figure 1 5 Safety Signs 3 of 5 6 HFDOV6LQJOH R IW...
Страница 14: ...1 8 9K998 INTRODUCTION AND SAFETY INFORMATION Figure 1 6 Safety Signs 4 of 5 6 HFDOV RXEOH R...
Страница 15: ...INTRODUCTION AND SAFETY INFORMATION 9K998 1 9 Figure 1 7 Safety Signs 5 of 5 6 LWFK HFDOV...
Страница 16: ...1 10 9K998 INTRODUCTION AND SAFETY INFORMATION Table provided for general use NOTES...
Страница 19: ...ASSEMBLY 9K998 2 3 Figure 2 4 3Pt Hitch RVH ODPS 0DQXDO ROGHU 3W LWFK 1XW RFN DVKHU 8 ROW UDPH 6 2S 3W LWFK...
Страница 25: ...ASSEMBLY 9K998 2 9 Table provided for general use NOTES...
Страница 31: ...ASSEMBLY 9K998 2 15 Table provided for general use NOTES...
Страница 36: ...2 20 9K998 ASSEMBLY Table provided for general use NOTES...
Страница 58: ...2 42 9K998 ASSEMBLY Table provided for general use NOTES...
Страница 80: ...3 22 9K998 OPERATION Table provided for general use NOTES...
Страница 92: ...4 12 9K998 MAINTENANCE Table provided for general use NOTES...
Страница 99: ......