OPERATION AND MAINTENANCE
4-11
Seed Shaft Monitor with Clutch
Control
Basic Operation:
During normal operation the monitor LED for each shaft
will not be illuminated. The shaft sensor will be activated
by a magnet attached to the shaft being monitored. The
shaft sensors are standard Loup shaft sensors, set to 20
second delay timing. When no signal is detected for 20
seconds by the sensor, the corresponding LED in the
console will illuminate and the audible alarm will sound
indicating a fault. The alarm will become silent after 30
seconds and will not sound again until all shafts return to
a fully functional condition. The LED for other shafts will
indicate a second fault but the alarm will not sound
unless all shafts are functional after the INITIAL alarm.
NOTE
If shaft sensor stall alarm occurs, be aware that the
affected seed box has not been planting for 20 seconds.
(See “Troubleshooting Guide” on page 5-1.)
The Clutch Master toggle switch allows you to go from
SEED to No SEED operations or you can control
individual clutches by toggling the appropriate switch.
Figure 4-9: Seed Shaft Monitor with Clutch Control