![Landis+Gyr ULTRACOLD T230 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/landis-gyr/ultracold-t230/ultracold-t230_manual_673728007.webp)
Contents
7/26
3
Technical Data
General
Measuring accuracy
Class 2 or 3 (EN 1434)
Environment class
A (EN 1434) for indoor installation
Mechanical class
M1 *)
Electromagnetic class
E1 *)
*) according to 2014/32/EU Directive on Measuring Instruments
Ambient humidity
< 93% rel. humidity at 25 °C, without
condensation
Max. height
2000 m above sea level
Storage temperature
-
20 … 60 °C
Electronic unit
Ambient temperature
5 … 55 °C
Housing protection rating
IP 54 according to EN 60529
Power supply
Battery for 6 or 11 years
Operation threshold for
T
0.2 K
Temperature difference
T
3 K … 80 K
Temperature measurement range
0 ... 180 °C
LCD
7 digit
Optical interface
Standard, EN 62056-21
Communication
Optional
Separability
Always, cable length 1.5 m
Temperature sensor
Type
Pt 500 according to EN 60751, not
detachable
Connection type
Pt 500, 2 wire technology
Cable length
1.5 m (optional 5 m)
Construction type
Bulb sensor ø 5.2 × 45 mm
Temperature range
0 ... 95 °C
Volume measurement unit
Protection class
IP 65 according to EN 60529
Mounting place
Hot side / cold side
Installation position
Any
Flow straightening
None
Measuring range
1:100
Temperature range
5
… 90 °C
National type approvals may be differ-
ent.
Maximum overload
qs = 2 x qp, permanent
Nominal pressure
PN16 (1.6 MPa; PS16)
qp m³/h
Overall length and connection
0.6
110 mm (3/4 '')
1.5
110 mm (3/4 '')
130 mm (1 '')
2.5
130 mm (1 '')