Lambda Control System/2 

LANDI RENZO S.p.A.

Installation and adjustament manual Lambda Control System/2

13/38

LAMBDA CONTROL SYSTEM/2 is a self-adjust-
ing electronic system to control the gas supply (Lpg
or Cng) of vehicles equipped with a lambda sen-
sor and catalytic converter: it requires no manual
adjustments and can automatically adapt to the
different environmental conditions and use of the
vehicle so as to ensure optimum carburation in
terms of driving, consumption and emissions.
LCS/2 electronically controls the regulation of gas
flow enabling the lambda factor to reach the val-
ues required at all speeds thanks to 2 electro-me-
chanical actuators. One actuator is fitted between
the reducer and mixer and determines the quan-
tity of gas at medium and high speeds (att-Max),
while the second actuator of the pressure reducer
ensures the proper gas flow for engine operation
at low speed (att-min), also maintaining this stable
with respect to accessories like conditioners, power
steering, etc. when these are operating.

1.

TECHNICAL SPECIFICATION

1.1 COMPUTER LCS/2
Electrical specifications:
- Power supply: 12V (-20% / +30%)
- Max. power absorption during operation: 0,6A
- Max. power applicable to the relay to interrupt

petrol injection (yellow wires): 6,5A

- Max. power output for gas control devices (blue

wires): 6,5A

- Water and dust protection level: IP65
Programmable functions
- Number of cylinders / type of ignition
- Type of engine rpm signal
- Type automatic petrol/gas change
- Petrol/gas switchover temperature (optional)
- Rpm number for automatic change
- Fuel overlapping time during automatic change
- TPS type (throttle position sensor)
- Gas level sensor type
- Type lambda sensor
- Lambda sensor reading delay
- Type of lambda sensor emulation
- Max. open throttle position during acceleration
- Min / max. actuator opening
- Cut-off option
- Fixed default option
- Memory resetting

1.2 LINEAR ELECTROMECHANICAL

ACTUATOR

Electrical specifications:
- Power supply: 12V
- Power absorption: 150mA
- Nominal power: 2W
- Operating temperature: -20°C / +120°C
- Water and dust protection level: IP65

2.

LCS/2 FUNCTIONS

LCS/2 is used with following Lpg or Cng 

LANDI

RENZO SE 81 STEP MOTOR and TN1/B STEP
MOTOR.
The LCS/2 Computer processes the signals from
the lambda sensor, ignition, throttle position sen-
sor TPS and holds in memory a lambda sensor
tension value corresponding to the stoichiometric
mixture that needs to be maintained for every op-
erating condition of the engine.
The lambda sensor in the exhaust manifold indi-
cates the mixture ratio and at every moment sends
a value of voltage to the LCS/2 Computer which
checks whether the mixture is correct by compar-
ing it with the value set in memory; if there is a
difference, the computer will drive the Linear Elec-
tromechanical Actuator, suitably changing the rate
of flow of gas until the mixture comes back into the
lambda stoichiometric value.
The main functions of the LAMBDA CONTROL
SYSTEM/2 include:

control of carburation during gas operation;
petrol starting with automatic switch over to gas,
also in relation to the engine temperature;
possibility of emergency gas starting by simple
operation on the switch;
electronic safety device that cuts off gas sole-
noid valve supply in the event of the engine ac-
cidentally stalling;
built-in relay to cut off petrol injection with auto-
matic change over to petrol in case of LCS/2
damage;
Petrol-Start function: the Linear Electromechani-
cal Actuator closes the gas line while running
on petrol and when the engine is stopped.
interface system (using a diagnostic connector)
with a diagnostic and programming instrument
Programmer - Tester V05 or Interface Kit V05
with dedicated software and serial interface for
personal Computer.

LEGEND (Fig. 1 Lpg; Fig. 2 Cng)
The system consists of the following components:

A) Computer LCS/2
B) Linear Electromechanical Actuator

Содержание LAMBDA CONTROL SYSTEM/2

Страница 1: ...678 Fax 39 0 522 382 906 E mail info landi it Internet Site http www landi it GB MANUALE INSTALLAZIONE E REGOLAZIONE pag 6 MANUEL AND ADJUSTMENT MANUAL page 20 INSTALLATION AND ADJUSTMENT MANUAL page...

Страница 2: ...Technical Drawings SchemiTecnici Sch masTechniques EsquemaT cnicos LANDI RENZO S p A Manuale di installazione e regolazione Lambda Control System 2 2 38 Fig 1...

Страница 3: ...Technical Drawings SchemiTecnici EsquemaT cnicos Sch masTechniques LANDI RENZO S p A Manuale di installazione e regolazione Lambda Control System 2 3 38 Fig 2...

Страница 4: ...Technical Drawings SchemiTecnici Sch masTechniques EsquemaT cnicos LANDI RENZO S p A Manuale di installazione e regolazione Lambda Control System 2 4 38 Fig 4 Fig 3 Fig 5 Fig 6 Fig 7...

Страница 5: ...Technical Drawings SchemiTecnici EsquemaT cnicos Sch masTechniques LANDI RENZO S p A Manuale di installazione e regolazione Lambda Control System 2 5 38 Fig 8 Fig 9 Fig 10...

Страница 6: ...apertura farfalla in fase di accelerazione Minima massima apertura attuatore Opzione cut off Opzione default fisso Reset memoria 1 2 ATTUATORE ELETTROMECCANICO LINEARE Caratteristiche elettriche Tensi...

Страница 7: ...ll interno del compu ter 4 INSTALLAZIONE ATTUATORE ELETTROMECCANICO LINEARE Fig 4 4 1 ATTUATORE MINIMO REGIME ATT MIN Il riduttore con attuatore elettromeccanico lineare deve essere posizionato parall...

Страница 8: ...ONDA LAMBDA Il collegamento della sonda lambda al cablaggio LCS 2 Fig 6 viene generalmente effettuato tra mite l interruzione del filo del segnale lambda ed il collegamento dei due capi ottenuti ai ri...

Страница 9: ...iniettori benzina di funzionare mentre quando il motore alimen tato a benzina i contatti restano chiusi Impostare il computer LCS 2 alla voce TEMPO DI SOVRAPPOSIZIONE il tempo desiderato in secon di...

Страница 10: ...cca Nella seconda pagina att indica in numero di passi la posizione in tempo reale dell attuatore elettromeccanico linea re per il minimo def indica in numero di passi la posizione di default acquisit...

Страница 11: ...o viene visualizzato se il tempo di sonda sconnessa maggiore di 0 5 Il parametro viene visualizzato se l opzione di affondata abilitata 6 Il parametro viene visualizzato se l opzione cut off abilitata...

Страница 12: ...pecifiche del veicolo e ripetere la verifica 6 Avviare il motore con il commutatore indicato re LCS 2 in posizione benzina ed attendere qualche minuto per permettere alla sonda lambda di scaldarsi 7 E...

Страница 13: ...ion Fixed default option Memory resetting 1 2 LINEAR ELECTROMECHANICAL ACTUATOR Electrical specifications Power supply 12V Power absorption 150mA Nominal power 2W Operating temperature 20 C 120 C Wate...

Страница 14: ...rked by the RED terminal from computer LCS 2 in the connector on the actuator For more details refer to the STEP MOTOR re ducer installation instructions inside the reducer pack 4 2 MEDIUM HIGH SPEED...

Страница 15: ...t of the most common types of lambda probes Single wire lambda probe determine the wire linking the lambda probe and the petrol computer Fig 6A two wire lambda probe determine the lambda signal wire u...

Страница 16: ...ICAL ACTUATOR CONNECTION The connector with the RED sheath on the end must be connected to the linear electromechani cal slow speed actuator att min located on the reducer SE81 STEP MOTOR part O Fig 1...

Страница 17: ...g position NOTE the electromechanical linear actuator of the medium and peak speeds is indicated on the dis play of the Programmer Tester V05 by the mes sage att Max the electromechanical linear slow...

Страница 18: ...RENZO MT012 The lambda sensor emulation of vehicles with Monoinjector Bosch for which the parameter TYPE OF TPS MONO BOSCH is made programming the parameter TYPE OF EMULATION GROUND On this vehicles t...

Страница 19: ...a probe learning range indicator on the data display page will begin to swing indi cating correct operation of the system at full speed 10 Gradually drop the engine speed to minimum By displaying the...

Страница 20: ...PS senseur position papillon Type senseur indicateur niveau gaz Type sonde lambda Retard lecture sonde lambda Type mulation sonde lambda Option maximum ouverture papillon en Acc l ration Minimum maxim...

Страница 21: ...TEUR ELECTRO MECANIQUE LINEAIRE Fig 4 4 1 ACTIONNEUR DE RALENTI ATT MIN Le d tendeur avec actionneur lectrom canique lin aire doit tre positionn parall lement au sens de marche du v hicule Introduire...

Страница 22: ...circuit de c blage du LCS 2 Fig 6 s effectue g n ralement en sectionnant le fil du signal lambda et en raccor dant les deux fils ainsi obtenus aux fils gris et vio let de l ordinateur LCS 2 Sur certai...

Страница 23: ...nd le moteur est aliment l essence les contacts restent fer mes Entrer l Ordinateur LCS 2 au param tre TEMPS DE SUPERPOSITION le temps n cessaire en se conds de retard de l ouverture de les contacts e...

Страница 24: ...en nombre de pas la position par d faut valeur standard de l actionneur lectrom canique lin aire de ralenti TOURS indique in t min le r gime moteur en temps r el TPS indique en volt la position du cap...

Страница 25: ...programm sur ONDE CARREE 4 Le param tre s affiche si le temps de sonde d connect e est sup rieur 0 5 Le param tre s affiche si l option acc l rateur fond est ABILITE 6 Le param tre s affiche si l opti...

Страница 26: ...teur LCS 2 en position essence et attendez quelque minute pour permettre a la sonde lambda de se chauffer 7 Entrer dans la page VISUALISATION duTesteur Programmateur ou du personal computer 8 Avec le...

Страница 27: ...ectura sonda lambda Tipo emulaci n sonda lambda Opci n m xima abertura mariposa en fase de aceleraci n M nima m xima abertura actuador Opci n cut off Opci n default fijo Reset memoria 1 2 ACTUADORE EL...

Страница 28: ...er dirigido hacia abajo para evitar que eventua les gotas de agua penetre dentro del Computer 4 INSTALACION ACTUADOR ELECTRO MECANICO LINEAR Fig 4 4 1 ACTUADOR R GIMEN RALENT ATT MIN El reductor con a...

Страница 29: ...riginal del im planto el ctrico del veh culo ex masa del computer gasolina o masa de otros dispositivos como ABS etc 6 2 HILOS GRIS Y VIOLETA DE CONEXI N SONDA LAMBDA La conexi n de la sonda lambda al...

Страница 30: ...r nivel gas 6 7 HILOS AMARILLOS EXCLUSION INYECTORES Los hilos amarillos del cableado LCS 2 son co nectados a los contactos de un rel normalmente cerrado Durante el funcionamiento a gas Fig 9A los con...

Страница 31: ...el TPS est en fase dei m nimo de velocidad de crucero o de m xima abertura de la mariposa de aceleraci n R M indican si la sonda es en fase de mezcla pobre o rica att indica en n mero de pasos la pos...

Страница 32: ...Actuador Max default fijo Deshabilitada habilitada Valor fijo default actuador Max 8 20 240 pasos Actuador min default fijo Deshabilitada habilitada Valor fijo default actuador min 9 20 160 pasos 1 E...

Страница 33: ...el veh culo ver par 7 2 5 Verificar de haber memorizado en el Computer LCS 2 las opciones exactamente correspon diente a las caracter sticas del veh culo En caso contrario hacer un reset de la memoria...

Страница 34: ...res por defecto del actuador del ralent att min y del actuador de los reg menes medios y altos att Max efec tuar un ensayo en carretera Datos descripciones e ilustraciones tienen un va lor meramente i...

Страница 35: ...A CONTROLLO ELETTRONICO SENZA LIMITAZIONI DI CILINDRATA PUO ESSERE MONTATO SUI VEICOLI RISPONDENTI ALLE DIRETTIVE 88 76 CEE 89 458 CEE SE CATALIZZATI 91 441 CEE 93 59 CEE SISTEMA DI ALIMENTAZIONE A G...

Страница 36: ...tico sia per il complesso di trasformazione a metano che a GPL CENTRALINA COMPUTERIZZATA DI CONTROLLO LANDI RENZO S p A LCS A G DGM 48522 GPL DEL 24 1 94 LCS A M DGM 48523 GM DEL 24 1 94 PUNZONATURA D...

Страница 37: ...A CONTROLLO ELETTRONICO SENZA LIMITAZIONI DI CILINDRATA PUO ESSERE MONTATO SUI VEICOLI RISPONDENTI ALLE DIRETTIVE 88 76 CEE 89 458 CEE SE CATALIZZATI 91 441 CEE 93 59 CEE SISTEMA DI ALIMENTAZIONE A M...

Страница 38: ...itivo attuatore di flusso e identico sia per il complesso di trasformazione a metano che a GPL LANDI RENZO S p A LCS A G DGM 48522 GPL DEL 24 1 94 LCS A M DGM 48523 GM DEL 24 1 94 PUNZONATURA DGM 5666...

Отзывы: