14
28-0752/02
2.7 FLOW RATE CHECK
The Dispenser’s water flow rate can be checked/calibrated using the on board computer as a timer. To check/adjust
flow rate:
STEP 1:
Remove splashguard and module cover to expose syrup flow controls and solenoids. Remove tower
cap to expose the soda and plain water flow controls.
All active brands should have their shutoffs in the open position as illustrated below.
CW = Carbonated Water (sparkling)
PW = Plain Water (still)
STEP 2
Press the A & B buttons for 5 seconds
simultaneously.
The Pour/Cancel button will illuminate and
the shot LED will blink 5 times.